Blendorama
Dispenser
Models 22PC & 22PD,
23PC & 23PD, 25PC &
25PD
Operating and
Maintenance
Manual
Part # - 5107070
Rev.G
05/19/03

Questions and Answers

  • B
    Becky PageAug 7, 2025
    What to do if my Fluid Management Blendorama 22PC does not agitate?
    • S
      Scott BarreraAug 7, 2025
      If the Fluid Management Dispenser doesn't agitate, first ensure the power cord is plugged into a properly grounded outlet and that the outlet has voltage. Check and reset the circuit breaker located on the unit's base, if necessary. Also, make sure canisters are correctly installed. Remove and reinstall them if needed. Hardened colorant in a canister can also cause this issue; clean the canister thoroughly. In some cases, the power switch may need replacement.
  • K
    kimbrianAug 11, 2025
    Why does my Fluid Management Dispenser unit mistint?
    • M
      mario58Aug 12, 2025
      If the Fluid Management Dispenser unit mistints, check the formula and gauge settings to rule out operator error. Inspect the gauges and gauge pins for wear, replacing the end cap assembly if needed. Calibrate the pumps following the calibration procedure. Remove any air from the pumps. Ensure colorant levels are adequate and agitate for several minutes to remove air from the system.
  • L
    Lauren SellersAug 16, 2025
    What to do if colorant does not dispense from Fluid Management Blendorama 22PC?
    • H
      Heather AllenAug 16, 2025
      If colorant doesn't dispense or is difficult to dispense from your Fluid Management Dispenser, first check if the canister is empty and refill it, then purge the system. A clogged nozzle can also cause this; remove and clean it thoroughly. If the colorant has hardened in the canister, remove the colorant and clean the canister. Finally, the nozzle might be too small; use the larger nozzle from the spare parts kit.
  • M
    Mike MartinezAug 20, 2025
    Why colorant does not dispense evenly from Fluid Management Blendorama 22PC Dispenser?
    • B
      Barbara McintoshAug 20, 2025
      If the Fluid Management Dispenser doesn't dispense colorant evenly or drips beforehand, it might be due to air trapped in the pump; purge the air from the system. Alternatively, the colorant level may be low; fill the canister and purge the system. A worn piston seal can also cause this issue, so replace the piston seal if necessary.
  • J
    John WallaceAug 25, 2025
    How to fix a loose canister on Fluid Management Blendorama 22PC?
    • B
      Brian SmithAug 26, 2025
      If a canister on your Fluid Management Dispenser is loose, check the mounting screws and tighten them until they are snug. If the canister mounting holes are stripped, you will need to replace the canister.
  • S
    Steven RobertsAug 28, 2025
    Why does colorant appear on piston shaft of Fluid Management Blendorama 22PC?
    • D
      David HoodAug 28, 2025
      If colorant appears on the piston shaft or gauges of your Fluid Management Dispenser, the piston seals are likely leaking and need to be replaced.
  • T
    Tonya LangSep 2, 2025
    What to do if end cap twists on Fluid Management Dispenser?
    • M
      Melissa WhitakerSep 2, 2025
      If the end cap of the pump tube twists or lifts during operation of your Fluid Management Dispenser, tighten the set screws in the end cap until it cannot be rotated. Be careful not to overtighten.

Fluid Management Blendorama 22PC Specifications