CABLES - IMPORTANT
Use only 1.00mm
2
size cable up to 40 metres
length maximum.
Maximum rating :
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR PRODUCT IS SUPPLIED WITH AN
ELECTRIC MAINS CABLE FITTED WITH A FEMALE
CONNECTOR
.
1. Flymo Mains Cables and Extension Cables are
available from your local Approved Service
Centre.
2. Do not wire an extension cable directly to your
product yourself. Please contact your local
Approved Service Centre for further information
on the connectors and kits available.
3. Only use extension cables specifically designed
for outdoor use.
CONNECTORS - IMPORTANT
Flymo connectors are suitable for use with 2 core
cable only. Under no circumstances should these
connectors be used for earthed products.
All Flymo connectors and cables are of
splashproof construction. They are not waterproof
and must not be left outside permanently nor
should they be submerged or immersed in water.
Do not let cable lay or trail through pools of water
or splashed with water from hose pipes.
MAINS PLUG REPLACEMENT - IMPORTANT
If the plug supplied is cut off it should be
destroyed. There is an electric shock hazard if a
cut off plug is inserted into a 13 amp socket.
1. No earth required. Flymo products are double
insulated to EN60335 and under no
circumstances should an earth be connected to
any part of the product.
2. Ensure the mains voltage suits your p
roduct
3. IMPORTANT!
The wir
es in the mains lead are coloured in
accordance with the following code:
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured BLUE must be
connected to the Terminal which is marked with
the letter 'N' or coloured BLACK.
The wire which is coloured BROWN must be
connected to the Terminal which is marked with
the letter 'L' or coloured RED.
4. It is important that the outer sheath is clamped
correctly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only
protect the electrical equipment and are not a
safeguard against electrocution.
Cables
IMPORTANT INFORMATION
When received from the
Manufacturer, the wheels are in a
raised position.
Do not switch on the product
before removing from the raised
position into position 5.
A
Roller Assembly
B1
1. Turn product over.
2. Place both halves of the roller over the location pegs
as illustrated in fig.B1
3. Clip the roller together to secure it into position.(B2)
Do not clip the roller together before placing over the
location pegs
B2
PAGE 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flymo MULTIMO 340XC and is the answer not in the manual?

Flymo MULTIMO 340XC Specifications

General IconGeneral
BrandFlymo
ModelMULTIMO 340XC
CategoryLawn Mower
LanguageEnglish

Related product manuals