EasyManua.ls Logo

Fonrich FR-DCMG-MMPS User Manual

Fonrich FR-DCMG-MMPS
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
Version 1.1
DC System MonitorFR-DCMG-MMPS
丰郅(上海)新能源科技有限公司
Fonrich (Shanghai) New Energy Technology Co., Ltd.
Add: 1st Floor, Building 5, No.999 Jiangyue Road, Minhang District,Shanghai
Web: www.fonrich.com
Tel: +86 21 61679671
Email: sales@fonrich.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fonrich FR-DCMG-MMPS and is the answer not in the manual?

Fonrich FR-DCMG-MMPS Specifications

General IconGeneral
BrandFonrich
ModelFR-DCMG-MMPS
CategoryMonitor
LanguageEnglish

Summary

Documentation statement

Product description

The main function

Details primary monitoring, display, alarm, and calibration capabilities.

Optional module

Describes available expansion modules for enhanced functionality like PLC communication.

Terminal description

Explains the purpose and meaning of each terminal on the FR-DCMG device.

(Optional) PLC expansion module terminal description

Details the terminals for the optional PLC expansion module.

Ground connection and RS485 communication shielded wire

Provides guidelines for proper grounding and RS485 shielded wire connections.

Wiring diagram of monitoring module

(Optional) PLC system network wiring diagram

Illustrates the network wiring for systems utilizing the optional PLC module.

UI introduction

Key operation

Explains the functions of the device's four keys (ESC, -, +, SET).

Boot interface

Shows the initial display screen shown after the device powers on.

Current interface

Describes the histogram interface displaying real-time current and status.

PLC status interface

Details the interface for viewing PLC communication status in different modes.

Initial interface display

Describes the factory default Modbus mode display and communication indicators.

Detailed data interface of channel current and power generation

Explains how to view detailed current and cumulative power generation data.

Parameter settings

Guides on accessing and configuring Modbus parameters like ADDR, PAR, and BPS.

Trip self-test setting interface

Details how to access and configure shunt trip settings and self-tests.

Current calibration setting interface

Explains the interface for performing current calibration (auto/manual).

System information display interface

Describes how to view system information, including software version.

Alarm status display interface

Explains how to view and clear alarm messages and statuses.

DC arc fault alarm interface

Shows the interface displayed when a DC arc fault is detected.

Fault alarm clear interface

Details the process for clearing fault alarms locally or remotely.

Alarm information management

Items that can generate alarms can be set

Lists the various parameters and conditions that can trigger alarms.

Items that can be tripped by setting

Lists parameters that can cause a trip action when configured.

Alarm conditions

Explains the specific conditions under which alarms are activated.

Alarm message

Describes the meaning of different alarm messages and their triggers.

Arc Alarm Strategy

Details the strategies and logic for handling arc alarms and trips.

MODBUS Protocol definition

Communication format configuration

Covers Modbus RTU mode settings like baud rate and byte check.

Data frame format description (refer to Modbus RTU standard)

Explains the structure of Modbus RTU data frames, including address, function, and data areas.

Function code description

Details the purpose of various Modbus function codes for reading/writing data.

Register reads and writes in bits

Describes Modbus function codes for bit-level register operations.

Register description.

Provides detailed descriptions of registers for bit-level operations.

Register description in word unit (function code 03 04 06)

Details registers for word-level Modbus operations.

PLC register:

Function code 03

Lists Modbus registers for function code 03, focusing on tonemap and communication quality.

Appendix

FAQ

Provides answers to frequently asked questions, including screen flicker troubleshooting.

Document revision record

Lists changes and updates made to the manual over different versions.

Contact us