Pressure Pump with Insulation Jacket
FMPP30
Installation and Maintenance Manual
Energy Conservation | Environment | Process Efficiency
www.forbesmarshall.com

Questions and Answers

  • J
    Joseph SmithAug 30, 2025
    How to fix Forbes Marshall FMPP30 Water Pump overflowing only during discharge?
    • C
      cassandracalderonAug 31, 2025
      If your Forbes Marshall Water Pump overflows only during discharge, inspect the inlet Check Valve. Lap the seat, and if the problem persists, replace the Check Valve.
  • A
    angelicatorresNov 9, 2025
    Why does my Forbes Marshall Water Pump stop working?
    • D
      Daryl BondNov 10, 2025
      Your Forbes Marshall Water Pump might stop working due to several reasons: the motive supply might be closed (open valves to supply motive pressure); the motive line strainer could be choked (clean the strainer); the condensate inlet line might be closed (open the condensate inlet valve); the condensate line strainer could be choked (clean the strainer); the condensate discharge line might be closed (open all discharge line valves); the motive pressure might be insufficient (adjust motive pressure to 2 barg more than total back pressure); the float might be punctured (replace the float); the check valve direction might be wrong (correct it); the steam might be coming out continuously from the exhaust line (clean or replace the leaking motive steam inlet valve); or the exhaust valve might b...
  • L
    Lindsay EvansNov 20, 2025
    What to do if Forbes Marshall Water Pump is continuously overflowing?
    • S
      Sara TuckerNov 20, 2025
      If your Forbes Marshall Water Pump is continuously overflowing, several factors could be responsible. The pump might be undersized, so verify the rated capacity and install an additional pump if needed. The inlet or motive line strainer could be partially choked; in this case, clean the strainer and ensure all valves are fully open. Live steam might be reaching the pump receiver, pressurizing it; check the steam trap for leakage and rectify it. Ensure the receiver vent line is open to the atmosphere as recommended. Insufficient motive pressure could also be the cause; check the motive pressure setting and back pressure, then increase motive pressure as required. The outlet check valve might be stuck open or leaking (clean or replace it if damaged). Confirm that the motive isolation valve i...