7
7. Troubleshooting
Problem Possible cause Possible solution
The appliance does not switch on. There is no power in the mains
supply socket.
Check fuse or cut-out
switch. Replace the
fuse or reset the
switch.
The appliance has weak suction
power.
dust bag is full. Empty the dust bag.
The dust escapes from the appliance. Filter is not installed correctly.
The brushes will not pick up any dust. Extension tube is clogged. Remove the tube and/
or brushes. Remove
the obstruction.
Heat produced during use. A small amount of heat is normally produced by the
vacuum during use.
Technical Specications:
Input voltage: 230V,AC,50Hz
Power (IEC): 1200W
Suction (at Mean Sea Level): 1700mm of WC(@MSL)
Unit weight: 3.6kg
Dimensions: 330mm×230mm×210mm