Re-sets the optional low level alarm, if your alarm is set in the latching mode.
NOTE: You must correct the low level condition (choose the applicable remedy):
Replace the CL2 or SO2 tank(s)
Fill the tank
before resetting the alarm. Silence the optional internal audible alarm by
pressing
ALARM RESET
THEN PRESS ENTER
ENTER TANK
TARE = XXXX
Press to reset.
Enter for YES....or
Enter for NO
DELETE
Continued . . .
IS TANK EMPTY ?
1 = Y O = N
0
1
ENTER
Step 1
Action Required - Press "ENTER" after completing each step.
Digital Display
Step 4
Step 5
Digital Display
Action Required - Press "ENTER" after completing each step.
Portable Tank:
Stationary Tank/Hopper:
ALARM RESET
SET SCALE ZERO / TARE
FIXED TANK APPLICATIONS cont . . . .
Using the Numeric Keys, input the TARE WEIGHT
(the weight of the empty tank and any other accessories)
QUESTIONS ? Help Hotline: 1-800-893-6723
W.2.106
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / info@forceflow.com
File: T4\O&M\AWZMSTR\WZDAY3B.tcw 11/99 (B10.pdf)