Detailed diagram illustrating the electronic carboy scale setup and components.
Lists model numbers, capacities, and tank diameter ranges for carboy scales.
Outlines the sequence of installation steps from platform placement to load cell anchoring.
Lists tools and materials needed for installing the carboy scale.
Describes the two main assemblies of the electronic carboy-scale.
Instructions for placing and positioning the scale platform on the floor.
Guidance on leveling the scale platform using shims.
Procedure for securing the platform to the floor with anchor bolts.
Instructions for anchoring the load cell to the floor.
Steps for mounting multiple scales side-by-side.
Instructions for placing a carboy onto the scale platform.
Directs users to follow specific instructions for tank loading.
Diagrams showing the front and bottom views of the indicator box.
Details on connecting conduits and cords to the indicator box.
Instructions for connecting the indicator to AC power.
Procedure for connecting load cells to the indicator.
Wiring instructions for 4-20 mA output signals.
Wiring for serial port communications with printers.
Information on connecting external apparatus using relays.
How to adjust the indicator's display angle.
Visual representation of the internal components of the Wizard indicator.
Checklist item for installing the scale platform and load cell.
Checklist item for mounting the indicator at the proper location.
Checklist item for wiring the indicator, emphasizing power off.
Checklist item for custom formatting the scale settings.
Checklist item for sealing the indicator enclosure to maintain NEMA 4X rating.
Checklist for initial power-up and verifying display readings.
Checklist steps for setting the scale zero for portable and fixed tanks.
Checklist steps for loading tanks in portable and fixed applications.
How to toggle between scale displays and view totals.
Functions for displaying percentage of full and setting time/date.
Procedures for tank loading and navigating menus.
Functions for selecting scales and toggling display information.
Quick reference for totals, percentage, and time/date functions.
Operations for tank loading and navigating menus downwards.
Step-by-step guide for loading portable tanks (auto/manual modes).
Procedure for filling tanks in fixed applications.
How to set low level alarm points for scales.
Displays the date and time the "Amount Used" was last cleared.
Resets the "Amount Used" and "Daily Usage" displays to zero.
Allows re-zeroing or entering tank tare weights.
Resets the optional low level alarm after correcting the condition.
Allows review of the past 10 days of chemical usage.
Instructions for printing display functions to a printer.
Example output format for scale reports.
Details on communication parameters for devices.
Configures display parameters like units, decimals, and resolution.
Allows field calibration of scale zero and span.
Sets feed rate units, sample time, and update period.
Configures display units to weight (lbs/kgs) or volume (gallons).
Controls automatic or manual display alternation and number of scales shown.
Sets manual or auto mode for loading tanks and entering tare weights.
Configures printer port settings like baud rate and line feeds.
Sets the current time and date for the indicator.
Allows verification or restoration of factory calibration factors.
Assigns unique identification numbers to each scale channel.
Configures set points for low-level alarms and relay operations.
Configures the 4-20 mA analog output for net weight or feed rate.
Option to delete existing factory calibration data.
Specifies which scale to calibrate.
Instruction to remove all weight for zeroing the scale.
Procedure to apply test weights and enter values for calibration.
Steps for centering the container within calibration rings for accurate readings.
Solutions for problems accessing menus or code set-up.
Troubleshooting incorrect AMOUNT USED, DAILY USAGE, or NET REMAINING values.
Solutions for non-operating alarms and printers.
Troubleshooting 4-20mA signals and erratic readouts.
Lists various parts for carboy scales, including platforms and backstops.
Lists indicator models and available accessories.