NOTE:
This function allows you to format your display by choosing various parameters like "lbs" or "kilos"; how many fixed zeros;
number of decimal places; your increments or "county by"; total number of digits or "resolution", and your capacity.
These Set-Up Codes allow you to custom format your scale for your specific application. They may be accessed when
initially installing your scale, but otherwise, very infrequently. You may change your default setting by entering the
4-digit numeric password and then pressing "ENTER". You may NOT access Set-Up codes while in the "MENU". You
must press delete to escape the Menu.
How many numbers right of the decimal point. Enter "O" or "1"
Example: 1 decimal place = 486.3 pounds.
NOTE: Most applications over 2,000 lbs. will use "O" decimal places.
NUMBER OF
DECIMALS _______
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
All Set-Up Codes have been factory set for your specific application and your
scale(s) has been calibrated.
Model Number of Scale/Sensor: ___________
Quantity of Scale Platforms: ________ (if applicable)
If any of the scale Set-Up functions are changed, your scale must be recalibrated.
WEIGHT UNITS
*LBS or KGS _______
Choose to read either "metric" or "imperial" units. Use arrow keys to select.
FIXED ZEROS ______
This function is displayed only if "0" decimal places is selected. This
represents how many "dead" zeros you want on your display. Enter "0" or "1".
Example: 1 fixed zero = 26,340
NOTE: Most applications under 20,000 lbs. will have "0" fixed zeros.
1, 2, OR 5
COUNT BY _______
Establishes the minimum increments of the display. Enter "1", "2" or "5".
Example: "1" = 1 lb. increments. "5" = 5 lb. increments. Choose 1, 2 or 5.
RESOLUTION
DIGITS = ________
Establishes the number of displayed increments or total "counts".
Choices: 1,000, 2,000, 3,000, 4,000, 8,000 or 12,000. Scroll the Menu Keys
until the desired resolution displays, then press ENTER.
NOTE: This number is not the total "capacity". Capacity will be the
automatic result of the "count by" and "resolution" entry.
CAPACITY _________
BY _________
Displays the result of the above selections. Push ENTER to accept.
SET-UP CODES
NOTE:
9080 SCALE SET-UP
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / info@forceflow.com
File: T4\O&M\AWZMSTR\WZSETUP1.tcw (B13.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F
L
L
O
O
Q
Q
I
I
U
U
P
P
W.2.201

Other manuals for Force Flow WIZARD 4000