POWER-UP: Scale display should read "NET WEIGHT REMAINING". The value will be the tare weight
of your SCALE PLATFORM(s) in "PORTABLE" Tank applications, or your VESSEL & PLATFORM in "FIXED" tank
applications.
Press and verify correct time and date. If incorrect, see SET-UP CODE 9087 (Section W.2.204).
Press until "SET SCALE ZERO" appears
on display. Zero scale as per instructions in Section
W.2.106 "Menu of Day-To-Day Operations". For
future reference, record ZERO FACTOR on a
sticker inside Wizard cover. Refer to Section
W.2.204 "Custom Formatting your Scale",
CODE 9088, to obtain zero factor.
Before LOADING Tank(s), press and wait
until Step 4 "CHANGE TANKS NOW" appears.
See instructions on Tank Load Mode Section W.2.103.
NOTE: If you load tank before reaching the "CHANGE TANK NOW" or the "FILL TANK NOW" step, your
usage data will be inaccurate.
TIME
DATE
TANK
LOAD
"PORTABLE" TANKS - Tank is REPLACED
2
1
START-UP CHECK-OFF LIST
Press until "CLEAR AMOUNT USED" appears on display. Clear the memory per
instructions in Menu of Day-To-Day Operations (Section W.2.105).
MENU
6
Apply pressure to platform to see if indicator responds to changes in weight.
3
Review SET-UP CODES, especially 9082, 9084, 9085 and 9089 (Starting at Section W.2.201)
4
QUESTIONS ? Help Hotline: 1-800-893-6723
W.1.305
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / info@forceflow.com
File: T4\O&M\AWZMSTR\CHKOFF.tcw (J10.pdf) 01/24/02 BD
FORCE FLOW
FORCE FLOW
F
F
L
L
O
O
Q
Q
I
I
U
U
P
P
MENU
With EMPTY tank on platform, press
until scale indicator reads "ENTER TARE". Zero scale as
per instructions in Section W.2.106 "Menu of Day-To-Day
Operations". For future reference, record ZERO FACTOR
on a sticker inside Wizard cover. Refer to Section W.2.204
"Custom Formatting your Scale", CODE 9088, to obtain
zero factor.
"FIXED" TANKS - Tank is REFILLED
MENU
"PORTABLE" TANK - Tank is REPLACED
"FIXED" TANK - Tank is REFILLED
Before FILLING Tank(s), press and proceed
as directed. Refer to "Operating Instructions",
Section W.2.103 TANK LOAD MODE.