ForestAir FDAH-36HDC-CDU - User Manual

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MODELS
Air Handlers : FDAH-24HDC-AHU, FDAH-36HDC-AHU
FDAH-48HDC-AHU, FDAH-60HDC-AHU
Outdoor Units : FDAH-24HDC-CDU, FDAH-36HDC-CDU
FDAH-48HDC-CDU, FDAH-60HDC-CDU
Electric Heaters : ET-1500, ET-2000
Sunrise Tradex Corp.
Saint-Mathieu-de-Beloeil, Quebec, Canada
ETECH-FDAH-18011 © Copyright, Sunrise Tradex Corp., 2018
Thank you for choosing our product. Please read this owner’s manual
carefully before operation and retain it for future reference.
Installation Manual

Questions and Answers

  • S
    Scott AdkinsAug 21, 2025
    How to fix signal communication failure between indoor and outdoor unit of ForestAir Air Handlers?
    • M
      Micheal PhillipsAug 21, 2025
      If you are experiencing signal communication failure between the indoor and outdoor units of your ForestAir Air Handlers, inspect the communication lines for any damage. If damage is found, replace the lines as necessary.
  • J
    Jonathan RodriguezAug 25, 2025
    What to do for overheat protection of discharge gas temperature in ForestAir Air Handlers?
    • P
      phelpsdavidAug 25, 2025
      If your ForestAir Air Handlers system is showing signs of overheat protection due to high discharge gas or compressor temperatures, allow the system some time to cool down. Also, make sure there is sufficient airflow around the unit.
  • A
    Alexis GarciaAug 26, 2025
    How to troubleshoot communication fault between wired controller and indoor unit in ForestAir Air Handlers?
    • R
      Ronald WhiteAug 26, 2025
      If you encounter a communication fault between the wired controller and the indoor unit of your ForestAir Air Handlers, the first step is to check the communication lines connecting these components.
  • K
    Krystal MckeeAug 28, 2025
    What to do if ForestAir Air Handlers show modular inverter board fault?
    • E
      Elizabeth GreenAug 28, 2025
      If you suspect a fault with the modular inverter board in your ForestAir Air Handlers, carefully inspect the board. If a fault is confirmed, replace the modular inverter board.
  • M
    Melissa JohnsonAug 30, 2025
    How to fix wired controller EEPROM fault in ForestAir Air Handlers?
    • J
      jessica07Aug 30, 2025
      If the wired controller of your ForestAir Air Handlers is showing an EEPROM fault, you should first check the wired controller itself. If the problem persists, consider replacing the controller.
  • G
    Gary GonzalezSep 1, 2025
    What to do if PCB of indoor unit is faulty in ForestAir Air Handlers?
    • D
      Diana CochranSep 1, 2025
      If you suspect a fault with the PCB of the indoor unit in your ForestAir Air Handlers, carefully inspect the PCB. If a fault is confirmed, replace the PCB.
  • G
    gstephensSep 3, 2025
    How to solve communication problem between PCB of outdoor unit modular inverter board in ForestAir Air Handlers?
    • M
      Mckenzie LopezSep 3, 2025
      If you are experiencing a communication problem between the PCBs of the outdoor unit's modular inverter board in your ForestAir Air Handlers, check all the connections and wiring to ensure they are properly connected and in good condition.
  • H
    holtoscarSep 5, 2025
    What to do if indoor unit surroundings temperature of system pressure is incorrect in ForestAir Air Handlers?
    • D
      Darius FitzgeraldSep 6, 2025
      If the indoor unit surroundings temperature of your ForestAir Air Handlers system is not reading correctly, inspect the indoor unit to ensure it is providing accurate temperature readings.
  • S
    Samuel BoyerSep 7, 2025
    How to fix outdoor unit fan coil temperature sensor fault in ForestAir Air Handlers?
    • Q
      qcannonSep 8, 2025
      If you suspect a fault with the outdoor unit fan coil temperature sensor in your ForestAir Air Handlers, replace the temperature sensor.
  • P
    Paul PayneSep 9, 2025
    How to fix outdoor unit surroundings temperature sensor fault in ForestAir Air Handlers?
    • R
      ryan42Sep 9, 2025
      If you suspect a fault with the outdoor unit surroundings temperature sensor in your ForestAir Air Handlers, replace the temperature sensor.

Summary

Safety Information

General Safety Warnings

Provides critical warnings regarding electrical hazards, qualified personnel, and safe operation.

Power Wiring

Control Wiring

Grounding

Electrical Data

Electric Kit MCA;MOP Data

Airflow Performance

Ductwork

Ductwork Design and Installation

Covers ductwork design, construction, insulation, and connection requirements.

Refrigerant Connections

Condensate Drain Tubing

Air Filter Requirements

Thermostat Control Keys

Thermostat Time and Timer Settings

Thermostat System Parameters

Troubleshooting Guide

Error Codes

Lists common error codes and their descriptions for diagnosing issues.

ForestAir FDAH-36HDC-CDU Specifications

General IconGeneral
Phase1
Hertz60 Hz
Fan Motor TypePSC
Weight120 lbs
Cooling Capacity36000 BTU/H
Voltage208-230V
Heating Capacity36000 BTU/H
Air Flow Rate1200 CFM