8
EN
OPERATING AND MOUNTING INSTRUCTIONS
S1 Safes according to EN 14450
Safes with a mechanical combination lock:
The mechanical combination lock comes with its own seperate manual.
Important: Please change the default factory code and replace it with your own code.
To change the factory code, there is a hole in the door trim panel at lock level, please remo-
ve the cover over the hole and insert the change key into the combination lock.
The door trim panel does not have to be dismantled!
2.2 Closing the door
Safes with a double bit key lock: (Right door hinge)
Pressthedoorrmlyshut,turnthedoorhandleanti-clockwisefullytotheleftandturnthe
key anti-clockwise to the left. Now pull the key out of the door.
For safes with door hinges on the left, the door handle must be turned clockwise when
closing to the right.
Important: Make sure the door is locked properly.
Important: Yoursafeisttedwithacertieddoublebitkeylockanda„aforcedlocking
key”. The key can only be removed if the lock is blocked.
Key loss: (for double bit key design only)
You will receive 2 double bit keys as standard. If one or more keys are lost, the lock must
be replaced for security reasons, otherwise the insurance cover will be voided. If you need
anadditionalkey,proceedasperthe„keyorder”formenclosed.
For security reasons, additional keys can generally only be made after an original key has
been presented.
Keep your keys in a safe place; in the event of loss, the vault must be opened by a service
technician.
3. ANCHORING AND ASSEMBLY
3.1 GENERAL
If you want to insure the contents of your safe, proper fastening of your safe with a dead
weightoflessthan1000kgisaminimumrequirementaccordingtotheEuropeancerti-
cation standard EN 14450. Agree on the conditions for installation and anchoring with your
property insurer.
Thesafecanonlyprovidemaximumprotectionafteritisxedtoasolidpartofthebuilding.
Please only use the anchoring holes provided in the vault to make the required xed
connection.Yoursafeisttedwithatleasttwoanchoringholesintheoororontherear
wall as standard. Depending on the model, your safe may also be provided with additional
anchoring holes.
Proper anchoring always has to be done with at least two anchorage holes. Appropriate
anchoring material is enclosed with the safe as standard.
2 x dowel M12S for metric screws M12
2 x hex screw DIN 933 M12x100 strength class 8.8
2 x washer DIN 125 D = 24 / 13 x 2.5 mm
If the supplied fastening material - due to the nature of the substrate - cannot be
used, the fastening material must be adapted to the conditions of the substrate
by client himself.