OWNER’S MANUAL / INSTALLATION GUIDE
Introduction
WV-01 is a patented, wireless, water detection and automatic water shut-off system that works as an automatic
valve for a home’s main water supply line and can be easily installed by a certified professional plumber.
WV-01 is a new professional grade, electrically operated water shut-off valve introduced by FortrezZ LLC.
Every year nearly 1 million families have their homes ruined and their lives overturned by water damage and the
subsequent repairs. The WV-01 used in a Z-Wave home automation network along with Z-Wave water alarm
sensors (WWA-0X), helps to reduce or eliminate water damage caused by leaky pipes or faulty appliances.
WV-01 can also work as a Water Level / Irrigation device. It can be set up to be on a ‘timed’ schedule using a
Smart Controller inside a Z-Wave home automation network.
WV-01 operates in a Z-Wave enabled home network which uses the latest and most successful wireless home
automation technology to provide protection 24/7, 365 days a year.
System Components
The Emergency Water Shut-off Valve System has two basic components:
1. A motorized ball valve and housing containing a wireless Z-Wave radio transceiver which automatically
turns off your water supply when any wireless water alarm sensor detects water or low, potentially
freezing temperature.
2. One or more wireless water alarm sensors (WWA-0X), which detect water from a leak or overflow, or
detect potentially freezing temperatures, and cause a wireless Z-Wave signal to be sent to the WV-01 to
turn off the water supply.
Question and Answer IconNeed help?

Do you have a question about the FortrezZ WV-01 and is the answer not in the manual?

Summary

Introduction

System Components

Motorized Ball Valve and Housing

Component with Z-Wave radio transceiver for automatic water shut-off.

Wireless Water Alarm Sensors (WWA-0 X)

Detects leaks/freezing, sends Z-Wave signal to shut off water.

Package Contents

Additional and Optional Components Available

Product Specifications

General Usage Specifications

Details on pressure, temperature, and application for the water valve.

Indicator Lights

Explains the meaning of red, green, and yellow indicator lights on the device.

General Safety Information

Installation and Code Compliance

Stresses adherence to codes and professional installation skills for safety.

Operational Safety Precautions

Highlights power disconnection, eye protection, and ball valve cautions.

Manually Test the Valve

Plug-in Testing Procedure

Instructions for testing the valve's open/close function after plugging in.

Operation

Front Panel Controls Overview

Describes the buttons, status light, and power-on behavior for manual operation.

Mode Indications

Water Valve Mode Status

Explains different modes indicated by fast blinks for network status.

Network Inclusion Modes

Automatic Network Wide Inclusion (NWI)

Details how NWI mode allows automatic inclusion into existing networks.

Manual Z-Wave Network Inclusion

Steps to add the valve to a Z-Wave network using a controller.

Z-Wave Network Management

Exclusion from Z-Wave Network

Procedure for removing the valve from a Z-Wave network.

Sensor Association

How to link sensors directly to the valve for immediate control.

Water Alarm vs. Water Level Modes

Explains default Water Alarm and Water Level modes for specific applications.

Manual Operation and Z-Wave Commands

Manual Operation (No AC or Battery)

Describes using the manual handle for shut-off during power outages.

Basic Command Class (Version 1)

Details how the valve responds to Basic Get/Set commands for position.

Binary Switch Command Class (Version 1)

Explains how the valve uses Binary Switch commands for open/close operations.

Advanced Z-Wave Command Classes

Manufacturer Specific & Version Classes

Describes Manufacturer Specific and Version command classes for device identification.

Configuration Command Class

Details how to switch modes and set water level timeouts.

Alarm Command Class (Version 2)

Explains how the valve signals power management events and battery status.

Troubleshooting and Compliance

Fault Conditions; Troubleshooting

Lists fault indications based on slow LED blinks and their corresponding causes.

USA FCC Compliance Statement

Details compliance with FCC rules for digital devices and transmitters.

Regulatory Compliance

RF Exposure Guidelines

Provides guidelines for safe human exposure to radio frequency fields.

Canada Industry Canada Statement

Outlines Industry Canada requirements for radio equipment.

Europe Certification

Notes the WV-01 module's certification for use in European countries.

How the System Works

Leak Detection and Shut-off

Explains how sensors detect leaks and instruct the valve to shut off water.

Review Location and Type of Main Supply Line

Recommended Installation Locations

Advises on where to install the shut-off valve indoors in the main water line.

Additional Part Requirements

Fittings for Copper Lines

Discusses common fittings for copper pipes and the need for appropriate connectors.

Steps of Installation using Compression Fittings

Compression Fitting Installation Guide

Step-by-step instructions for installing the valve using compression fittings.

Installation Completion and Soldering

Finalizing Compression Fitting Installation

Steps to position, tighten, and test the valve after compression fitting installation.

Solder Fittings Method

Describes soldering as an alternative installation method requiring professional skill.

Placement of Water Alarm Sensors WWA-0 x

Suggested Sensor Locations

Lists recommended areas for placing water alarm sensors to detect leaks.

Operating the Water Valve WV-01

Major Repairs and System Operation

Guidance on closing valves during major repairs and manual cycling.

Test Procedure

System Testing Steps

Detailed steps to test the water valve system after installation and configuration.

General Safety Information

Warnings and Precautions

Lists critical warnings about unit usage, power, and handling.

Emergency Procedures

Manual Operation During Emergencies

Explains how to manually operate the valve during power outages or damage.

System Limitations and Warnings

RF Interference and System Reliability

Notes that wireless transmissions can be subject to RF interference.

Life Support Application Warning

States the system must not be used in life support or safety-critical applications.

LIMITED WARRANTY

Manufacturers One Year Warranty

Details the terms and conditions of the limited manufacturer's warranty.

Returns and Refund Policy

Information on returning the product for exchange or refund within 30 days.

FortrezZ WV-01 Specifications

General IconGeneral
BrandFortrezZ
ModelWV-01
CategoryControl Unit
LanguageEnglish