4.2.6.1
Tools
required
for
adjustment
Oscilloscope
Tape
tension
gauge
:
Tentel
Model
T2-H20-ML
Blank
tape
:
1/2"
width,
Ampex
456
4.2.6.2
Procedure
1)
Loosen
the
screws
(a)
and
(b).
2)
Tighten
the
screws
(a)
and
(b)
to
hold
the
bracket
(c)
horizontally.
3)
However,
in
case
the
optimum
tension
value
cannot
be
obtained
by
adjusting
the
pots
RI
thru
R6
in
the
following
tension
adjustment
procedures,
loosen
the
screw
(a)
and
(b)
and
adjust
the
position
of
the
Tension
arm
bracket
for
x
direction
or
x
direction
for
optimum
tension
value.
If
the
Tension
arm
bracket
is
adjusted
too
far
x
direction,
the
shut
off
circuit
may
be
activated.
4.2.6.3
Tape
Tension
Adjustment
Tape
tension
measurement
will
slightly
differ
due
to
scattered
calibration
figures
of
the
tension
gauge
and
ambient
temperature
differences
from
that
at
manufacture
of
the
gauge.
If
the
measurement
is
only
for
checking,
it
will
be
sufficient
if
preparations
are
made
as
in
Item
4.2.6.4
and
checked
as
explained
in
Item
4.2.6.9.
Fig.
4.7
4.2.6.4
Preparation
1)
Load
10-16
inch
reels
wound
with
about
the
same
amount
of
tape
on
both
left
and
right
reel
turntables.