I. Introduction
Fountain Tech pumps are carefully inspected and tested to insure
both safety and operating performance. However, failure to
follow the instructions and warnings in this manual may result
in pump damage and/or serious injury. Please read and save this
manual for future reference.
II. Performance
° A clogged or dirty intake screen will greatly reduce perfor-
mance. If the pump is used on a dirty surface, raise it slightly to
reduce the amount of debris contacting the Intake.
Fountain TECH FT-105 Pump
CAUTION
ALWAYS DISCONNECT THE PUMP FROM THE ELECTRI-
CAL OUTLET BEFORE HANDLING.
DO NOT LET THE PUMP RUN DRY.
DO NOT LIFT THE PUMP BY THE POWER CORD.
DO NOT PUMP HEATED LIQUIDS.
OPERATE IN FRESH WATER ONLY.
OPERATE PUMP COMPLETELY SUBMERGED FOR PROPER
COOLING.
WARNING
° This pump is supplied with grounding connector and a
grounding type attachment plug. To reduce the risk of electric
shock, connect only to a properly grounded outlet.
° Do not remove the grounding pin from the plug.
° Do not connect any voltage other than that shown on the
pump.
° Do not pump ammable liquids.
° The National Electric Code requires that a Ground Fault
Circuit Interrupter (GFCI) be used in the branch circuit supply-
ing fountain pumps and other pump equipment. See your local
electrical supplies dealer for this device.
° To reduce the risk of electrical shock, use only on portable
self contained fountains no larger than 5 feet in any dimension.
° Do not use with water above 86° F.
Failure to observe any of these safety precautions may result in
pump damage and/or serious injury.
28
24
20
16
12
8
4
H
e
i
g
h
t
26 52 79 105 132
Gallons Per Hour
° If less ow is desired, adjust the ow control lever on the side of
the pump or restrict the discharge ow.
° Do not allow the pump to run when not submerged. Doing so may
damage the pump. Always submerge the pump rst and then plug in
the electrical cord.
° It is common for there to be air in the pump and tube when rst
plugged in. Pull the electrical cord out and re-insert it until the uid
begins to ow.
° This pump comes with multiple connector tubes. If desired, re-
move and insert other size.
III. Maintainance
To clean the pump, remove the front plate and the impeller. Use a
small brush or stream of water to remove any debris. CAUTION:
The pump shaft can not be removed. IF THE PUMP FAILS TO
OPERATE, CHECK THE FOLLOWING:
° Check the circuit breaker and try another outlet to insure the pump
is getting power. NOTE: Always disconnect the pump from the
electrical outlet before handling the pump.
° Check the pump discharge and tubing for kinks and obstructions.
Algae buildup can be ushed with a garden hose.
° Check the inlet screen to insure it is not clogged with debris.
° Remove the pump inlet to access the impeller area. Turn the rotor
assembly to insure that it is not broken or jammed.
° Monthly maintainance will add to your pump’s life.
NOTE: Insure that the electrical cord loops below the electrical
outlet to form a “Drip Loop”. This will prevent water from running
down the cord into the electrical outlet.
FT-105.indd 1 1/4/2008 6:03:29 PM
Question and Answer IconNeed help?

Do you have a question about the Fountain TECH FT-105 and is the answer not in the manual?

Summary

Introduction

Performance

Clogged Intake Screen Impact

A clogged or dirty intake screen will greatly reduce performance. Raise pump slightly to reduce debris contact.

Flow Rate Adjustment

Adjust flow control lever or restrict discharge flow for desired flow rate. Always submerge pump before plugging in.

Prevent Running Pump Dry

Do not run the pump when not submerged. Always submerge pump before plugging in to avoid damage.

Addressing Air in Pump

Air in pump/tube is common. Unplug and re-insert cord until fluid begins to flow.

Connector Tube Usage

The pump includes multiple connector tubes. Remove and insert others as desired for different sizes.

Maintenance and Troubleshooting

Pump Cleaning Procedure

Remove front plate and impeller. Use brush or water to remove debris. Pump shaft is not removable.

Troubleshooting Pump Failure

Check breaker, outlet, kinks, obstructions, and inlet screen. Ensure rotor is not broken or jammed.

Routine Maintenance Benefits

Monthly maintenance is recommended to extend the pump's lifespan. Ensure a 'Drip Loop' for the power cord.

Safety Precautions

General Electrical Safety

Always disconnect pump before handling. Do not run dry, lift by cord, pump hot liquids, or use with voltage other than shown.

Operating Environment

Operate in fresh water only, completely submerged for cooling. Do not use with water above 86° F.

Grounding and Shock Prevention

Use grounding connector and outlet. Do not remove grounding pin. Use GFCI. Limit use to portable fountains up to 5 ft.

Warranty Information

Fountain TECH Guarantee

12-month guarantee against defects. Void if product is misused or tampered with. Requires receipt for claims.

Record Keeping

Keep purchase date, model number, and dealer name for warranty records.

Pump Components

FT-105 Pump Diagram

Diagram illustrating pump components including front cover, impeller, pump body, and power cord.

Overview

The Fountain TECH FT-105 is a submersible pump designed for use in fountains and similar applications. It is engineered for safety and operating performance, with a 12-month warranty that is void if the product is misused or tampered with.

Function Description:

The primary function of the FT-105 pump is to circulate water. It is designed to be fully submerged during operation, which is essential for proper cooling and to prevent damage. The pump is suitable for use in portable self-contained fountains no larger than 5 feet in any dimension. It is equipped with a grounding connector and a grounding type attachment plug to reduce the risk of electric shock, and must be connected only to a properly grounded outlet. The National Electric Code requires the use of a Ground Fault Circuit Interrupter (GFCI) in the branch circuit supplying fountain pumps and other pump equipment for safety.

Important Technical Specifications:

  • Flow Rate: The pump's flow chart indicates various flow rates depending on the head height. For example, at 0 feet of head, the pump can deliver approximately 132 gallons per hour (GPH). As the head height increases, the flow rate decreases:
    • 26 GPH at approximately 28 feet of head
    • 52 GPH at approximately 24 feet of head
    • 79 GPH at approximately 20 feet of head
    • 105 GPH at approximately 16 feet of head
    • 132 GPH at 12 feet of head (and lower)
  • Water Temperature: The pump should not be used with water above 86°F (30°C).
  • Liquid Type: The pump is designed to operate in fresh water only and should not be used to pump heated liquids or flammable liquids.
  • Electrical: The pump requires a specific voltage (not explicitly stated in the provided text, but implied to be shown on the pump itself) and must be connected to a properly grounded outlet. The grounding pin on the plug should never be removed.

Usage Features:

  • Submersible Operation: The pump must always be fully submerged before being plugged in. Running the pump dry will cause damage.
  • Flow Control: The pump features a flow control lever on its side, allowing users to adjust or restrict the discharge flow if less flow is desired.
  • Air Removal: It is common for air to be present in the pump and tube when first plugged in. To resolve this, users should pull the electrical cord out and re-insert it until fluid begins to flow.
  • Connector Tubes: The pump comes with multiple connector tubes of different sizes, which can be interchanged as needed.
  • Intake Screen: A clogged or dirty intake screen will significantly reduce performance. If the pump is used on a dirty surface, it should be raised slightly to minimize debris contact with the intake.
  • Safety Precautions:
    • Always disconnect the pump from the electrical outlet before handling.
    • Do not lift the pump by the power cord.
    • Do not pump heated or flammable liquids.
    • Operate only in fresh water.
    • Ensure the pump is completely submerged for proper cooling.
    • Do not remove the grounding pin from the plug.
    • Do not connect any voltage other than that shown on the pump.
    • Use only in portable self-contained fountains no larger than 5 feet in any dimension.
    • Do not use with water above 86°F.
    • Ensure the electrical cord loops below the electrical outlet to form a "Drip Loop" to prevent water from running down the cord into the electrical outlet.

Maintenance Features:

  • Cleaning: To clean the pump, the front plate and the impeller should be removed. A small brush or stream of water can then be used to remove any debris. The pump shaft cannot be removed.
  • Troubleshooting (If pump fails to operate):
    • Power Check: Verify the circuit breaker and try another outlet to ensure the pump is receiving power. Always disconnect the pump from the electrical outlet before handling.
    • Obstruction Check: Inspect the pump discharge and tubing for kinks and obstructions. Algae buildup can be flushed with a garden hose.
    • Inlet Screen Check: Ensure the inlet screen is not clogged with debris.
    • Impeller Area Check: Remove the pump inlet to access the impeller area. Turn the rotor assembly to ensure it is not broken or jammed.
  • Monthly Maintenance: Regular monthly maintenance is recommended to extend the pump's life.

Warranty and Support:

Fountain TECH guarantees the product for 12 months. The guarantee is void if the product is misused or tampered with. For warranty claims, customers must include the receipt with the defective pump. If found defective, Fountain TECH will repair or replace it. Contact information for Fountain TECH is provided:

  • Address: 2351 Thompson Way, #C-2, Santa Maria, CA 93455
  • Phone: (805) 928-7410
  • Website: www.fountaintechpumps.com