31
ENGLISH
2) To be performed every year even if the specified operating hours
interval has not been reached.
3) The frequencies are applicable for lubricants which meet the
standards as specified in the REFILLING table.
4) Only use filters with the following specifications:
- degree of filtering < 12 μm
- filtering efficiency 99.5% (ß > 200).
5) To be performed every two years even if the specified operating
hours interval has not been reached.
6) To be performed every three years even if the specified operating
hours interval has not been reached.
7) To be performed every 15 days even if the specified operating
hours interval has not been reached.
8) To be performed every six months even if the specified operating
hours interval has not been reached.
1) For applications operating in dusty environments.
2) To be performed every year even if the specified interval of
operating hours has not been reached.
3) To be performed every two years even if the specified number of
operating hours has not been reached.
The extraordinary maintenance operations described
hereunder fall within the exclusive competence of
manufacturer’s personnel or specialised personnel
having proper working tools and adequate protection
devices. The procedure and modality for carrying out
these operations are illustrated in the FPT Technical
and Repair Manual.
Scheduled maintenance of
ATS system
Action
Tank pre-filter (300 μm or 100 μm
(1)
)
No maintenance antici-
pated (clean if neces-
sary)
Pre-filter supply module
(100 μm or 70 μm
(1)
)
Clean with water each
time the oil is changed
(2)
AdBlue inlet filter to supply module
(100 μm)
No maintenance antici-
pated (clean if neces-
sary)
Filter supply module
Replace every 1200
hours
(3)
AdBlue return filter from supply module to
tank (100 μm)
No maintenance antici-
pated (clean if neces-
sary)
Dosing module filter (36 μm) Not serviceable