BEFORE CALLING FOR SERVICE
Problem
Possibile causa
Soluzione
Not working
No power supply
Connect to a functioning outlet and switch on.
Water Full Indication Flashes
Drain water tank and reset it, or re-position the
water tank to right place
Room temperature ˂ 5°C,or ˃ 35 °C
Self-Protection designed to protect the unit. Can
not work under such temperature
Bad functioning
Is the filter clogged ?
Clean the air filter as instructed
Is the intake duct or discharge duct
obstructed?
Remove the obstruction from the discharge duct or
intake duct.
No air intake
Is the filter clogged ?
Clean the air filter
Loud noise when
running
Is the machine put in the plat place?
Put the machine on a plat ground
Is the filter clogged ?
Clean the air filter
E1
Humidity/temperature sensor problem
Change the sensor
5.6 Spare parts
Should it be necessary to replace one or more parts during maintenance by specialized operators,
this must be done using only original spare parts.
If necessary, request the "spare parts list" from your dealer specifying the model and serial number
of the unit.
5.7 Storage
Long-term storage - If you will not be using the unit for an extended period of time (more than a few
weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following
steps:
Press power button to switch off and unplug the unit.
Drain the remaining water from the unit.
Clean the filter and let the filter dry completely in a shaded area.
Collect the power cord at the water tank.
Re-install the filter at its position.
The unit must be kept in upright position when in storage.
Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
5.8 Decommissioning
The device has been designed and built to guarantee continuous operation. The duration of some
main components, such as the fan and the compressor, depends on the maintenance to which they
have been subjected.
________________________________________
Warning: The unit contains substances and components that are dangerous for the environment
(electronic components, refrigerant gas and oils). At the end of the useful life, in case of dismantling
of the unit, the operation must be performed by specialized refrigeration personnel. The unit must
be assigned to special specialized centres for the collection and disposal of equipment containing
dangerous substances. The refrigerant and the lubricating oil contained in the circuit must be
recovered, in accordance with the regulations in force in your country.