Franke HT-400 - No or Delayed Water Flow; Water Boiling or Vapor Appears

Franke HT-400
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HT-400
Under Sink Heating Tank Installation Instructions and Use and Care Guide
11
WHAT TO DOPROBLEM POSSIBLE CAUSE
TROUBLESHOOTING
continued:
Water does notow
right away or at all:
Due to high temperature and for
safety reasons, the tank is not
under pressure causing a slight
delay in waterow.
Make sure all valves on water supply are open.
Check hose from faucet for twisting or tight bending.
Water boils or vapor
appears:
The thermostat may be set too
high.
Lower temperature setting by turning temperature
control dial counter clockwise.
Turn off the water main supply line. Disconnect the
water inlet and quick connect from tank. Point the
tube in a bucket or container. Turn on the main
water supply valve. If water does not ow out, it
means that the tube
is clogged. Remove the tube
and clear the clog.