EasyManua.ls Logo

Franke TX 604 V11 - Error Codes and Troubleshooting

Franke TX 604 V11
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Safety functions and error display.
ERROR CODE ERROR DESCRIPTION INSTRUCTION MANUAL
ER03 & permanent tone
Permanent use of keys; Control unit cuts
off after 10 sec; Water or cooking
utensils on the glass above the control
unit.
If the problem persists, CONTACT
AUTHORIZED CENTER FOR
TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER21
Control unit cuts off due to overheating to
avoid damage to electronics.
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
U400
Secondary voltage of the power unit to
high (primary > 300V). Control unit cuts
off after 1 sec releasing a permanent
tone.Control unit is wrongly connected.
1) CONTACT AUTHORIZED
CENTER FOR TECHNICAL
ASSISTANCE - SPECIFYING THE
ERROR CODE
2) Contact an electrician to check the
home supply mains.
ER22
Key evaluation defective. Control unit
cuts off after 3.5 - 7.5 sec.Short-circuit or
discontinuation in the range of the key
evaluation.
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER36
NTC value is not within its specification
(value < 200mV or > 4.9V; control unit
cuts off.Short-circuit or cut-off at NTC.
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER20
Flash-failure. Microcontroller faulty. CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER40
Secondary operational voltage is to low
for min.5 s (1,8V< UPowerfail< 2,9V).
Primary PTC too hot.
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE

Related product manuals