Air drawn in at top, blown out at high velocity, creating a protective air shield.
Units installed horizontally over doorways; can be surface mounted or recessed.
Wiring by competent electrician per IEE regulations; remove front plate for access.
Ensure intake/exhaust is clear; surfaces are hot; do not cover unit.
Check power supply, airflow selector, and position limit switch if fans are still.
Disconnect power, investigate fault, and reset overheat protector by pressing red button.
Disconnect electricity before cleaning; clean components annually.
Rectifies moisture in heating element by connecting via socket without safety cut-out.
| Voltage | 230 V |
|---|---|
| Frequency | 50 Hz |
| Protection | Overheat protection |
| IP rating | IP21 |
| Mounting | Wall mounting |
| Length | 2040 mm |