Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 5) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
A 50A time-delay fuse or circuit breaker is recommended
(minimum 40A).
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see Figure 5):
1. Be sure that no power is supplied on the cable from
residence.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. In the circuit breaker, fuse box or junction box:
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
Neutral _ I _ Black
(white) Wire _ -__ Wires
Red ":":::::_i_::;-_S
i_jdres_ _ !_IWires -
[_]b _->.._\_ I Junction
__ _"" WhiteB_/_ire
Green J _L_/_ "U.L.-listed Conduit
(or Bare Copper) X-7is Connector (or CSA
Wire Cable from listed)
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
Figure 5
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 6):
1. Be sure that no power is supplied on the cable from
residence.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. In the circuit breaker, fuse box or junction box:
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit breaker,
fuse box or junction box.
Cablefrom Residence
Green(or Bare
Copper)Wire '_ _,,_:_.---_
White Wire
_(,_..__ Wires]
Green(or Bare ___4,,I _dp. /
Copper)Wi
__'_-- White Wire
Junction _t_ -_LLL-listed Conduit
Box _::_x_ .......
............... Connector (or CSA
Cablefrom listed)
Appliance
NOTE:Besureto removethe
suppliedgrounding strap. _"
Figure 6 - 4-Wire Electrical System
(Example: Junction Box)
7