IMPORTANT SAFETY NOTICE
The information provided herein
is designed to assist qualified
repair personnel only. Untrained
persons should not attempt to
make repairs due to the possibili-
ty of electrical shock. Disconnect
power cord before servicing.
216787900
SERVICE DATA SHEET
COMPACT CHEST
FREEZER
INSTALLATION
This product is designed for “free standing installation only” and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The floor or mounting surface should be level and capable of supporting the
weight of the freezer when it is fully loaded.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
9.5°F cut in, -9.2°F cut-out @ number 1 setting
PERFORMANCE (Control @ number 1 setting)
Room Ambient 70°F 90°F
Freezer Compartment Temperature 5 to 8°F 5 to 8°F
Percent Running Time 25-35% 40-50%
*Wattage Range (Last
1
⁄3 of cycle) 65-85 70-85
Suction Pressure (Cut-in, cut-out), PSIG 12-0 12-0
High Side Pressure (Last
1
⁄3
of cycle), PSIG 110-130 145-165
Specifications subject to change without notice.
*For complete performance data by model refer to service manual. PD640
IMPORTANT
If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.