“go to TABLE OF CONTENTS
53 FRIULINOX ALI GROUPS.R.L. A SOCIO UNICO
Via Treviso,4 - 33083 Taiedo di Chions (PN) -Italy
Service Manual
8.6.7. Condenser probe replacement
1. Loosen the central screw closing the front panel using a
screwdriver.
2. Lift the front panel, being careful to secure it to the
rear body.
3. Remove the electric box by loosening the two locking
screws using a screwdriver.
4. The condenser probe is identified by the YELLOW
connector.
5. Loosen the probe connections from the board.
6. Cut the probe ties.