EasyManua.ls Logo

Friulinox Cube Series - Page 52

Friulinox Cube Series
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
“go to TABLE OF CONTENTS
FRIULINOX ALI GROUPS.R.L. A SOCIO UNICO 52
Via Treviso,4 - 33083 Taiedo di Chions (PN) -Italy
Service Manual
7. Lift and remove the protective casing from its seat,
paying attention to the compensation valve, if any.
8. Cut the ties. The probe is located on the side of the
evaporator.
9. Replace the probe.
10. Secure the ties and connect the probe to the board.
11. Reposition the casing, closing it with the belt
12. Close the electric box and the central panel, paying
attention to the door microswitch.