Before installing the parapet anchor Frontline requires that the substrate
withstand the required 5,000 lbs minimum breaking strength and approved
before use by a qualified person. The parapet wall must be a minimum of 10” high
so that the adjustable arm lies flat and unobstructed and the parapet wall be of a
maximum width of no greater than 15”. If the parapet wall meets these criterias,
then follow the instructions below in order to proceed to installation:
1. Position the parapet’s adjustable arm and fixed arm in between the parapet
wall with the d-ring anchor facing outwards towards fall hazard as shown on
figure 5.
a. Parapet anchor needs to be straight, flush and plumed against the outer
wall.
BUILDING