PF50 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 4: OPERATING/FILTERING INSTRUCTIONS
4-1
4.1 Filter Operation
WARNING
Use care when draining and filtering oil to avoid the possibility of a serious burn.
1. Sprinkle 8 ounces (1 cup) of filter powder over the filter paper, distributing the powder as evenly
as possible. If filtering a second frypot immediately after the first, add only 4 ounces of filter
powder for the second filtering.
2. Ensure the power cord is securely plugged into the receptacle on the back of the portable filter
(115V domestic units only). Plug the power cord into an 115V (domestic) or 230V (export)
receptacle.
3. If solid shortening is filtered through the portable filter, turn the Heater/Filter switch to HEATER
(see illustration below- PF50 panel shown). The white indicator light will illuminate. Leave the
heater on for 20-30 minutes before operating the filter.
Note: The filter pump cannot be activated while the switch is in the "Heater" position.
4. Ensure the Suction/Off/Return (PF50) or Off/Return (PF50S) switch is OFF. Turn the
Heater/Filter switch to FILTER for filter operation (see illustration below). The red indicator
light will illuminate.
Use the filter heater for 20-30 minutes prior to filtering if solid shortening is filtered.
The Heater/Filter switch must be in the FILTER position before the filter pump can