EasyManua.ls Logo

FT Technologies FT702LT - Page 50

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6 Parameter Settings
50 FT702LT Flat Front Wind Sensor Manual
6.4.17 SN: Query the Serial Number and Build Version
Command
Parameter
SN
Command
Syntax
SET Sensor:
NA
QUERY Sensor:
$<listenerID>,SN?*<checksum><cr><lf>
$aa,SN?*hh<cr><lf>
FT702LT output:
$<talkerID>,SN=<SerialNumber>,<BuildVersion>*<check
sum><cr><lf>
$aa,SN=xxxxx-xxx,xxsss*hh<cr><lf>
Parameters
<SerialNumber>
00000-000 to
99999-999
Unique serial number of the sensor
<BuildVersion>
00-99
Build version (issue) of the sensor design. The 3 spaces after the 2
digit number are reserved for future use.
Examples
Example 1
Read the sensor serial number and build version
Message
Comment
$01,SN?*//<cr><lf>
Query serial number
$WI,SN=02350-130,06 *33<cr><lf>
FT702LT response
Description
The SN command returns the serial number of the sensor and also the build version of
the sensor.
The serial number format starts with a 5 digit batch code, followed by a 3 digit number
which identifies a sensor within a particular batch. The overall number is the unique
serial number identifier for the sensor.
The build version is a 2 digit number which identifies the design version of the sensor.
For example, this will be 22 for all version 22 sensors.