5
EN
WB-O2 Nano
4. WB-O2 Meter Nano Electric Installation
The WB-02 Nano has a 12-way connector with 3 wire groups. One of them has
the connector for the O2 sensor, the second makes the CAN communication
with Power FT ECU’s and the third is responsible for power and analog output.
By default, the analog output is set to values of 8.7AFR to 16.2AFR Gas, but
can be configured to 5.14AFR to 17.6AFR Gas or 9.55 to 19.11AFR or 9.55
to 58.80AFR or yet 9.55 to 146.9AFR (Gas), if necessary.
See the following wiring diagram for details about connections.
12-way connector
Wire color Pin Connection OBS
Red 1 O2 sensor O2 sensor pin 6 - IP
Yellow 2 O2 sensor O2 sensor pin 5 - sensor negative signal
Brown 3 O2 sensor O2 sensor pin1 - Sensor positive signal
Red 4 Switched 12V The use of a 10A fuse is recommended
Yellow/Red 5
0-5V Analog
Output
Analog output proportional to the lambda readings. Used
for connection with data acquisition systems
White/Red 6 CAN CAN (+): connected to Power FT ECU’s CAN port
Orange 7 O2 sensor O2 sensor pin 2 - sensor resistor calibration
Green 8 O2 sensor O2 sensor pin 3 - sensor heater positive
Blue 9 O2 sensor O2 sensor pin 4 - Sensor heater negative signal
Black/White 10
Chassis/
Engine Power
Ground
Engine ground (head/block)
Do not connect it directly to the battery negative.
Black 11
Battery’s
Negative
Connected directly to the battery negative with no
splices. Do not connected this wire to the chassis
engine block or head.
Yellow/Blue 12 CAN CAN (-): connected to Power FT ECU’s CAN port