3.4
3.5
3.6
No
When taking off tapping belt,
twist pulley of knead ball unit,
twist easily?
Exchange knead ball unit
Service no.「19」
es
Exchange tapping motor
Types of connecting equipment of control unit and remote
control unit are different.
Connect right remote controller or control unit.
Service No.「11」
Service No.「14」
Is 11P cord for control side Mechanic inserted surely connector
(CN8) ?
No
Connect connector surely
Service No.「18」
Exchange control basement board
es
es
Is junction connector of Mechanic 11P cord surely inserted ?
No
Connect connector surely
es
Is there any break of Mechanic side 11P cord, control side 11P
code ?
No
es
Exchange concerned cord。
Is Mechanic side 11P code surely connected to connector (CN3)
of junction basement board ?
No
Connect connector surely
es
Is HL sensor cord surely connected to connector of junction
basement board (CN2) ?
Is HL sensor cord surely connected to connector of HL sensor
basement board (CN1) ?
No
Connect connector surely
Is there any break of HL sensor cord ?
No
es
Exchange HL sensor cord