5. OUTDOOR FAN CONTROL
Following table 3 shows the fan speed of the outdoor unit.
01-17
1. Outdoor Fan Motor
*
It runs at 500rpm for 20 seconds after starting up the outdoor fan.
When the outdoor heat exchanger temperature is lower than 1°C,
the fan speed switches to 780rpm on heating mode.
When the outdoor heat exchanger temperature is lower than 2°C,
the fan speed switches to 850rpm on heating mode.
( Table 3 : Fan speed of the outdoor unit )
780/ 730/ 400/ 300/ 250/ 200 rpm
780/ 730/ 660/ 400/ 300/ 250/ 200 rpm
Cooling
Heating
AO*G18LAT3
AO*G18/ 24LAT3
AO*G30LAT4
AO*G30LAT4
850/ 820/ 780/ 400/ 300/ 200 rpm
850/ 780/ 400/ 300/ 200 rpm
AO*G24LAT3