EasyManuals Logo

Fujitsu AB*G14LVTA Service Instructions

Fujitsu AB*G14LVTA
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
01-02
START
Room temp.
Ts + 2
°C?
COOLING (AUTO:DRY)
OPERATION
HEATING OPERATION
YES
YES
NO
NO
NO
AUTO CHANGEOVER operation flow chart
TS : Setting temperature
Room temp.
Ts - 2
°C?
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
NO
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
Middle zone
NO
Operation mode
of outdoor unit : Cooling or Dry?
YES
NO
Operation mode
of outdoor unit : Heating?
YES
NO
YES
Outdoor temperature
25°C?
NO
YES
YES
NO
YES
YES
When Heating was selected at , the same operation as HEATING OPERATION of page
01-02 is performed.
When the compressor was stopped for 6 consecutive minutes by the temperature control function
after the Cooling(Auto:Dry) or Heating mode was selected at above, operation is switched
to Monitoring and the operation mode is selected again.
3
1
4
1

Other manuals for Fujitsu AB*G14LVTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AB*G14LVTA and is the answer not in the manual?

Fujitsu AB*G14LVTA Specifications

General IconGeneral
BrandFujitsu
ModelAB*G14LVTA
CategoryAir Conditioner
LanguageEnglish

Related product manuals