EasyManuals Logo

Fujitsu ABHG54KRTA User Manual

Fujitsu ABHG54KRTA
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
3-2. Outdoor unit—No power
Forecast of cause
Power supply failure
External cause
Electrical components defective
Check point 1. Check installation condition
Isn’t the breaker down?
Check loose or removed connection cable.
→ If abnormal condition is found, correct it by referring to the installation manual or the “DESIGN &
TECHNICAL MANUAL”.
Check point 2. Check external cause at indoor and outdoor (voltage drop or noise)
Instant drop: Check if there is a large load electric apparatus in the same circuit.
Momentary power failure: Check if there is a defective contact or leak current in the power sup-
ply circuit.
Noise: Check if there is any equipment causing harmonic wave near electric line. (Neon bulb or
electric equipment that may cause harmonic wave)
Check the complete insulation of grounding.
Check point 3. Check electrical components
Check the voltage of power supply.
Check if AC 198 to 264 V appears at outdoor unit terminal L — N
→ If no, go to "Check point 1" and "Check point 2".
+
-
Check fuse in main PCB.
If fuse is open, check if the wiring between terminal and main PCB is loose, and replace fuse.
Check point 4. Replace main PCB
If check point 1 to 3 do not improve the symptom, change main PCB.
End
3-2. Outdoor unit—No power - (03-43) - 3. Troubleshooting without error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ABHG54KRTA and is the answer not in the manual?

Fujitsu ABHG54KRTA Specifications

General IconGeneral
BrandFujitsu
ModelABHG54KRTA
CategoryAir Conditioner
LanguageEnglish

Related product manuals