EasyManua.ls Logo

Fujitsu ABYG45LRTA - Refrigerant System Schematic; Outdoor Unit Refrigerant Flow; Indoor Unit Refrigerant Flow

Fujitsu ABYG45LRTA
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REFRIGERANT SYSTEM DIAGRAM
2013.02.15
Thermistor (Compressor)
Compressor
4-way
Valve
Pressure
Check Valve
Pressure
Sensor
Muffler
Check
Valve
Strainer Strainer
Expansion
Valve
Muffler
3-way Valve
3-way Valve
Accumulator
High Pressure
Switch
Refrigerant Pipe
9.52mm (3/8")
Refrigerant Pipe
15.88mm (5/8")
Thermistor (Discharge)
Thermistor (Room)
Heat
Exchanger
Heat
Exchanger
Thermistor (Pipe)
Thermistor (Heat Exchanger Med)
Thermistor (Heat Exchanger Out)
Thermistor (Outdoor)
Cool
Refrigerant direction
Heat
3
OUTDOOR UNIT INDOOR UNIT
www.enindel.com