En-6
The following conditions may not be breakdowns so
check again.
Does not operate at all:
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the main power switch set to the OFF position?
Are you trying to engage in an operation different from the priority
state? (Refer to "OPERATING TIPS")
Is it in standby state? (Refer to "OPERATING TIPS")
Is the Auto-off operation of the Human sensor setting active? (Refer to
"HUMAN SENSOR")
The operation mode cannot be changed:
Are you trying to change to an operation different from the priority
conditions? (Refer to "OPERATING TIPS")
Poor Cooling (or Heating) performance:
Did you adjust the temperature setting correctly?
Is the air lter dirty? (Refer to "CLEANING AND CARE")
Are the air conditioner’s inlet port or outlet port blocked?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
Is the fan speed set to low?
Is the Auto saving operation of the Human sensor setting active? (Re-
fer to "HUMAN SENSOR")
Temperature does not fall down well:
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.) (Refer to "OP-
ERATING TIPS")
Set the temperature lower than the room temperature.
In the following situations, stop operation immediately
and get in touch with authorized service personnel.
The problem cannot be solved even when the troubleshooting checks
have been performed.
The Filter indicator lamp (red) is blinking very fast.
The wired remote controller or simple remote controller indicate "Er"
(when connected).
It has burning smell.
SPECIFICATIONS
MODEL
ASUA4
TLAV2
ASUA7
TLAV2
ASUA9
TLAV2
ASUA12
TLAV2
ASUA14
TLAV2
POWER SOURCE 208/230 V ~ 60 Hz
AVAILABLE
VOLTAGE RANGE
187 to 253 V
COOLING
CAPACITY
Btu/h
(kW)
4,000
(1.2)
7,500
(2.2)
9,500
(2.8)
12,000
(3.5)
14,000
(4.2)
HEATING
CAPACITY
Btu/h
(kW)
4,400
(1.3)
9,500
(2.8)
10,900
(3.2)
13,500
(4.0)
15,600
(4.6)
SOUND PRESSURE LEVEL
HIGH
dB [A]
31 34 37 40 44
MED - HIGH
dB [A]
30 32 35 37 42
MED
dB [A]
28 30 32 35 40
MED - LOW
dB [A]
27 28 29 33 37
LOW
dB [A]
26 26 26 30 34
QUIET
dB [A]
22 22 22 24 24
DIMENSIONS & WEIGHT
HEIGHT
[in (mm)]
10-9/16 (268)
WIDTH
[in (mm)]
33-1/16 (840)
DEPTH
[in (mm)]
8 (203)
WEIGHT
[lbs (kg)]
19 (8.5) 20 (9)
Acoustic Noise Information:
The maximum sound pressure level is less than 70 dB (A) for both
indoor unit and outdoor unit. According IEC 704-1 and ISO 3744.
9377772435_OM.indb 69377772435_OM.indb 6 7/28/2020 10:30:26 AM7/28/2020 10:30:26 AM