3-3. CASSETTE TYPE
MODELS : AUUB18TLAV, AUUB24TLAV
AUUB18, AUUB24
Refrigerant pipe are
connection
Liquid ø 3/8 (9.52)
Gas ø 5/8 (15.88)
Drain hose ø 3/4 (I.D.), ø 1-1/16 (O.D.)
Unit : in. (mm)
37-3/8 (950)
IR receiver
(Option)
37-3/8 (950)
View A
31-5/16 (796)
Hanging bolt position
Drain hose
14-1/8 (358)
33-1/16 (840):Indoor unit
23-7/8 (607)
16-9/16 (420)
27-1/2 (699)
Hanging bolt position
33-7/8 to 35-13/16 (860 to 910)
Ceiling opening
9-13/16 (250)
1-1/4 (31) 1-1/4 (31)
5-5/8 (143)
Fresh air inlet
(cut out) 2-3/4(70)
A
View B
5-9/16 (142)
5-9/16 (142)
Ceiling
B
(Control Box)
7-7/8 (200)
3/8 (10)
14-1/8 (358) 10-15/16 (278)
2-3/8 (60)
1-3/4 (44)
1-9/16 (40)
Wire hole
5-1/2 (140)
C
10-1/16 (256)
4-5/16 (109)
3-9/16 (90)
13-7/8 (352)
3-1/4 (83) 3-1/4 (83)
3-15/16 (100) 3-15/16 (100)
View C
5-5/8 (143)