CONTENTS
1. TEST RUN
1-3 CHECK ITEMS AFTER POWER ON.........................................................................
1-2-1 Power source inspection......................................................................................
1-2-2 Outdoor unit field setting inspection.....................................................................
1-2 CHECK ITEMS BEFORE POWER ON.......................................................................
1-1 EXECUTION PROCEDURE AND EXECUTION PRECAUTIONS.............................
1-2-4 RB unit field setting inspection.............................................................................
01-01
01-03
01-03
01-04
01-05
1-2-3 Indoor unit field setting inspection.....................................................................
... 01-04
01-12
1-4 TEST RUN OPERATION........................................................................................... 01-16
2-1 REFRIGERANT CIRCUIT..........................................................................................
2. OUTDOOR UNIT OPERATION CONTROL
2-2 INPUT / OUTPUT LIST...............................................................................................
02-01
02-02
02-03
02-05
2-4-4 Compressor Sequence Operation.......................................................................
2-4-
3 Capacity control...................................................................................................
2-4-1 Operation / Stop Condition..................................................................................
02-03
2-3-1 Operation mode selection and controlling...........................................................
02-01
2-1-1 Refrigerant circuit for Outdoor air unit.................................................................
02-06
2-8 SPECIAL OPERATION...............................................................................................
02-11
02-11
02-11
2-8-2 Pre-Heat Operation.............................................................................................
2-8-1 Oil Recovery Operation.......................................................................................
2-8-3 Defrost Operation Control.................................
...................................................
02-12
2-6 FAN CONTROL..........................................................................................................
02-08
2-7 EXPANSION VALVE CONTROL...............................................................................
02-10
02-08
02-14
2-8-4 Low noise mode...................................................................................................
2-6-1 Cooling / Cooling main operation........................................................................
02-09
2-6-2 Heating / Heating main operation........................................................................
1-2-5 Transmission wire installation inspection............................................................. 01-06
1-2-6 Piping installation
inspection................................................................................ 01-09
1-2-7 Refrigerant charge amount inspection................................................................. 01-11
1-2-8 3-way valve opening inspection........................................................................... 01-11
1-3-1 Power source check...........................................
.................................................
1-3-2 Error indication check..........................................................................................
1-3-4 Transmission line connection check.....................................................................
01-12
01-12
01-14
1-3-3 Installed unit and their addresses check......................................................
........ 01-13
1-3-5 Operation check sheet.......................................................................................... 01-15
1-4-1 Test Run from outdoor unit PC board................................................................
1-4-2 Test Run From remote controller.......................................................................
01-16
01-17
1-5 TEST RUN CONTROL...............................................................................................
01-20
1-6 FIELD SETTING / FUNCTION SETTING FOR OUTOOR UNIT................................
01-21
1-7 FIELD SETTING / FUNCTION SETTING FOR INOOR UNIT....................................
01-25
1-8 FIELD SETTING / FUNCTION SETTING FOR OUTDOOR AIR UNIT......................
01-26
2-3 HEAT RECOVERY OPERATION CONTROL............................................................ 02-03
2-4 COMPRESSOR OPERATION.................................................................................... 02-03
02-04
2-4-2 Compressor speed control..................................................................................
02-07
2-5-1 Operation mode selection and controlling...........................................................
2-5 HEAT EXCHANGER CONTROL................................................................................
02-07
02-07
2-5-2 Capacity control...................................................................................................
02-15
2-8-5 Snow Falling Protection Fan Mode -Default Setting -..........................................
+1