SERVICE MANUAL
208/230V 60Hz

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Airstage VR-II ARUH60TLAV and is the answer not in the manual?

Fujitsu Airstage VR-II ARUH60TLAV Specifications

General IconGeneral
ModelARUH60TLAV
CategoryAir Conditioner
BrandFujitsu
SeriesAirstage VR-II
RefrigerantR410A
Outdoor Unit Dimensions (WxHxD)340 mm

Summary

TEST RUN

EXECUTION PROCEDURE AND EXECUTION PRECAUTIONS

Detailed steps and precautions for executing the test run procedure.

Check Items Before Power ON

List of items to check before applying power to the system.

Transmission wire installation inspection sheet 1/3

Inspects transmission wire installation and network system setup.

Piping installation inspection sheet 1/2

Inspects refrigerant piping installation, including insulation and length.

Refrigerant charge amount inspection sheet

Procedure for inspecting the refrigerant charge amount.

Check Items After Power ON

Post-power checks for system operation.

Error indication check sheet 1/2

Checking for error indications and LED status on various components.

Transmission line connection check sheet

Checks transmission line connections for correct operation.

Operation check sheet

Verifies system operation parameters like pressures and temperatures.

Test Run Operation

System functional testing procedures.

Test Run From Outdoor unit PC Board

Step-by-step guide for performing test runs via the outdoor unit PC board.

Test Run From Remote Controller

Instructions for conducting test runs using various remote controllers.

TEST RUN CONTROL

Explains how test runs are controlled and operating modes.

Field Setting And Monitor Mode List for Outdoor unit

Lists field settings and monitor modes for outdoor units.

Field Setting / Function Setting for Indoor unit

Details field settings and functions for indoor units via remote controller.

Field Setting / Function Setting for Outdoor air unit

Details field settings and functions for outdoor air units.

OUTDOOR UNIT OPERATION CONTROL

INPUT / OUTPUT LIST

Lists system inputs, outputs, and their control ranges.

COMPRESSOR OPERATION

Details compressor operation, conditions, and modes.

Operation / Stop Condition

Specifies conditions for compressor operation and stopping.

Compressor speed control

Explains compressor speed control ranges and influencing factors.

Capacity Control

Details compressor capacity control and system pressure control.

HEAT EXCHANGER CAPACITY CONTROL

Controls heat exchanger capacity based on operation modes.

EXPANSION VALVE CONTROL

Controls electronic expansion valves for refrigerant flow.

PROTECTIVE FUNCTION

Functions that protect the system from abnormal conditions.

Discharge temperature protection

Protects against high discharge temperatures.

INDOOR UNIT AND RB UNIT OPERATION

FAN CONTROL

Controls fan speed and operation modes for indoor units.

MASTER CONTROL

Manages system-wide operations and priorities.

TROUBLE SHOOTING

ABNORMAL OPERATION

Covers troubleshooting of abnormal system conditions.

Error code Display

Explains the structure and meaning of error codes.

Trouble shooting index - Error code List 1/2

Comprehensive index for troubleshooting error codes.

Trouble shooting index - No Error code

Troubleshooting steps for issues without specific error codes.

TROUBLE SHOOTING WITH ERROR CODE

Troubleshooting steps for indoor unit communication errors.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA1.1)

Troubleshooting for Discharge Temperature 1 Abnormal errors.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA3.1)

Troubleshooting for Compressor 1 Temperature Abnormal errors.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA4.1)

Troubleshooting for High Pressure Abnormal errors.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA4.2)

Troubleshooting for High Pressure Protection 1 errors.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA5.1)

Troubleshooting for Low Pressure Abnormal errors.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA6.3)

Troubleshooting for Heat Ex.1 Gas Temp Sensor Error.

TROUBLE SHOOTING WITH ERROR CODE (continued - EA6.4)

Troubleshooting for Heat Ex.2 Gas Temp Sensor Error.

TROUBLE SHOOTING WITH ERROR CODE (continued - EAC.4)

Troubleshooting for Outdoor unit Heat Sink Temperature Abnormal.

TROUBLE SHOOTING WITH ERROR CODE (continued - EJ1.1)

Troubleshooting for RB Unit EEPROM Access Abnormal.

TROUBLE SHOOTING WITH ERROR CODE (continued - EJ1.4)

Troubleshooting for RB Unit transmission PCB2 parallel communication error.

TROUBLE SHOOTING WITH ERROR CODE (continued - E71.1)

Troubleshooting for Initial Setting Error.

TROUBLE SHOOTING NO ERROR CODE

Step-by-step troubleshooting for issues without specific error codes.

DISASSEMBLY PROCESS

Outdoor Unit

Procedures for accessing outdoor unit components.

Compressor removal

Precautions and procedure for compressor removal and replacement.