¢ Floor type
Rotation number range of compressor
Unit: rps
Model name Outdoor temperature zone Operating rotation number
AGHG09KVCA
AGHG12KVCA
AGHG14KVCA
X zone 50
J zone 50
Y zone 0
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5°C
Ts-0.5°C
Ts+1.5°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
1-3. Dry operation - (04-22) - 1. Rotation number control of compressor