EasyManuals Logo

Fujitsu AO G12KATA Series Service Manual

Fujitsu AO G12KATA Series
471 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #231 background imageLoading...
Page #231 background image
Check point 4. Check serial signal (Reverse transfer signal)
Check serial signal (Reverse transfer signal)
RED
WHITE
BLACK
+
-
3
2
1
• Check if indicated value swings between AC 90 V and AC 270 V at the outdoor unit terminal 1
—3.
• If it is abnormal, check the parts below.
– Outdoor unit fan motor in "Service parts information" on page 03-83
– Active filter module in "Service parts information"
• If outdoor fan motor is abnormal, replace outdoor unit fan motor and main PCB.
• If active filter module is abnormal, replace it.
• If the checked parts are normal, replace the main PCB.
↓
End
Check point 1-2. Check external cause such as noise
• Check the complete insulation of the grounding.
• Check if there is any equipment that causes harmonic wave near the power cable (Neon light
bulb or any electronic equipment which causes harmonic wave).
↓
End
2-1. E: 11. Serial communication error (Serial reverse transfer error) (Outdoor unit) - (03-15) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu AO G12KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G12KATA Series and is the answer not in the manual?

Fujitsu AO G12KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G12KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals