¢ Ceiling type
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOHG30KBTA4
AOHG36KBTA5
10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ABHG18KRTA
ABHG22KRTA
A zone 111 74 63 46
B zone 120 87 74 54
C zone 130 111 94 80
D zone 130 130 130 130
¢ Floor type
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOHG30KBTA4
AOHG36KBTA5
10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
AGHG09KVCA
AGHG12KVCA
AGHG14KVCA
A zone 102 74 63 54
B zone 102 87 74 63
C zone 130 111 94 80
D zone 130 130 130 130
1-1. Cooling operation - (04-8) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND