6. Press the MODE button once to transmit the function mode information.
2 short beeps
7. Press the
/
button once to transmit the function setting information. 2 short beeps will be
emitted from the indoor unit when the signal is received correctly. If wrong code is set, no beep
sound will be emitted.
2 short beeps
NOTE:
Press
/
button within 30 seconds after pressing MODE button.
For the function details, refer to Chapter 1-5. "Function details" on page 05-38.
8. Exit the function setting mode by pressing the RESET button.
RESET

Setting up each indoor unit
Repeat step from 1. to 8. to set up each indoor unit. If the custom code is other than " ", steps from
1. to 2. and 8. need to be performed.
1-2. Indoor unit (setting by wireless remote controller)
- (05-11) - 1. Function settings (for indoor unit)