Do you have a question about the Fujitsu AOU24D1 and is the answer not in the manual?
Explanation of safety symbols used in the manual, including danger, warning, and caution.
Details on how the unit operates automatically based on room settings.
Explanation of the sleep timer function that adjusts thermostat settings automatically.
Information on the convenience and use of the wireless remote control.
Description of how the louvers swing to distribute airflow.
Details on the removable grille for easy cleaning and maintenance.
Information about the filter treated to resist mildew for cleaner use.
Explanation of the QUIET mode for reduced airflow and noise.
Details on the power diffuser feature for warming feet in heating mode.
Identification and description of parts for the indoor unit.
Identification and description of parts for the outdoor unit.
Identification and description of parts for the remote control unit.
Instructions for turning on the power and loading batteries into the remote control.
Step-by-step guide to setting the current time on the remote control.
Guidance on operating the unit using the remote control and its holder.
How to choose between AUTO, HEAT, COOL, DRY, and FAN modes.
Instructions for adjusting the temperature settings for different modes.
Guide to selecting fan speeds, including AUTO, HIGH, MED, LOW, and QUIET.
Details on how the unit automatically selects mode and thermostat settings.
Steps to set the unit to turn on or off at a specific time.
How to set a sequence of ON and OFF timer operations.
Procedures for canceling timers or modifying existing settings.
How to activate the sleep timer to automatically adjust temperature.
Explanation of how the sleep timer modifies thermostat settings for comfort.
How to adjust the up-down airflow direction using the remote control.
Instructions for manually adjusting the left-right airflow direction.
How to activate the louvers' automatic swing function.
Procedure to deactivate the automatic swing function.
Details on the different airflow directions available during swing.
How to operate the unit using the controls on the main unit.
Instructions for cleaning the indoor unit with a cloth.
Guidance on preparing the unit for storage longer than one month.
Recommendation for regular professional maintenance and inspections.
Checks for common problems like no operation, noise, smells, weak airflow, and water production.
A checklist for diagnosing issues such as no operation or poor cooling/heating performance.
Factors affecting heating performance, especially at low outdoor temperatures.
How the unit restarts automatically after a power interruption.
Explanation of the microcomputer-controlled automatic defrosting feature.
This document is an operating manual for a Fujitsu Heat & Cool Model (Reverse Cycle) Room Air Conditioner, specifically a Multi Split Type designed for two rooms.
The Fujitsu Multi Split Type Room Air Conditioner is designed for both heating and cooling, operating on a reverse cycle. It offers various modes of operation including Automatic, Heating, Cooling, Dry, and Fan, allowing users to select the most suitable mode based on room temperature and desired comfort. The unit is controlled via a wireless remote control unit, which provides convenient access to all functions.
Automatic Operation: By simply pressing the START/STOP button, the unit automatically begins operation in either Heating, Cooling, Dry, or Monitor modes, adjusting according to the thermostat setting and the actual room temperature. The system intelligently selects the operating mode and standard thermostat settings when operation begins. For instance, if the room temperature is 88°F or above, it will cool to 82°F; if it's below 74°F, it will dry to 68°F. The fan runs at a very low speed for about one minute at the start to detect and select the proper operating mode. Once set, the mode will not change even if the room temperature fluctuates. If the unit is restarted within two hours of stopping, it will resume operation in the same mode as before.
Cooling Mode: This mode is used to cool the room. The thermostat should be set lower than the current room temperature for the cooling function to operate. If set higher, only the fan will operate.
Dry Mode: Designed for gentle cooling while dehumidifying the room. Heating is not available in this mode. The unit operates at a low fan speed, and the fan may stop intermittently to adjust room humidity. The fan speed cannot be manually changed in Dry mode.
Fan Mode: Used to circulate warm air from the ceiling area throughout the room, especially when using space heaters. The fan operates when the room temperature rises above the set thermostat temperature and stops when it drops. If the emitted air feels too cool, the thermostat setting can be raised.
Timer Operation: The unit features ON, OFF, and Program timers.
Sleep Timer Operation: This function prevents excessive warming or cooling during sleep by automatically modifying the thermostat setting.
Swing Operation: The Air Flow Direction Louvers automatically swing up and down to distribute air evenly throughout the room. This operation can be temporarily paused if the fan is not running or operating at very low speeds. The airflow direction cannot be adjusted manually during swing operation.
Manual Auto Operation: In cases where the remote control unit is lost or unavailable, the unit can be operated using the MANUAL AUTO button on the main unit control panel. In this mode, the unit operates under the same AUTO mode settings as the remote control unit, with the fan speed set to "AUTO" and the thermostat at 76°F.
Indoor Unit Models:
Outdoor Unit Models:
Thermostat Setting Range:
Operating Temperature and Humidity Range:
Remote Control Unit:
Microcomputer-controlled Automatic Defrosting: During heating in low outdoor temperatures and high humidity, frost can form on the outdoor unit, reducing performance. The unit is equipped with an automatic defrosting function that temporarily stops operation for 7 to 15 minutes to clear frost. During this time, the OPERATION Indicator Lamp (red) will flash.
| Cooling Capacity (BTU/hr) | 24000 |
|---|---|
| Refrigerant | R410A |
| Cooling Capacity | 7.03 kW |
| Coefficient of Performance (COP) | 3.5 |
| Heating Capacity (BTU/hr) | 24000 |
| HSPF | 9.0 |
| Noise Level (Outdoor) | 52 dB |
| Power Supply | 208-230V, 60Hz, 1 Phase |