Setting DescriptionFunction Number
Setting Value
Standard insulation
95
00
01
High insulation
Setting DescriptionFunction Number Setting Value
Standard setting
-1°F (-0.5°C)
-2°F (-1.0°C)
-4°F (-2.0°C)
-3°F (-1.5°C)
-5°F (-2.5°C)
-6°F (-3.0°C)
-7°F (-3.5°C)
-8°F (-4.0°C)
No correction 0.0°F (0.0°C)
00
01
02
03
04
05
06
07
08
09
31
(For
heating)
Less
Heating
Too Warm
Is insulation level greater than R-13.
Trouble shooting 36
Forecast of Cause
Check Point 1 : Check insulation level of structure
of house
Check Point 1-1 : Check Function Setting
If insulation level is greater than R-13 set function95 to 01.
Ref.)
Using the table on the right adjust function 31.
(Room Temperature Control for indoor unit sensor)
Ref.)
Check Point 4 : Check Function Settings
Check Point 3 : Check the remote controller display
Check Point 2 : Verfity room temperature sensing location
“Indoor unit sensor”
“Wired remote sensor”
Do you want room temperature sensed at the
wired remote controller (Wired remote sensor) or
by they build in sensor inside the unit (Indoor unit sensor).
Check Point 1-2 : Check effects of Function Setting change
Is the space still too warm in relation to set point.
Too warm
TO NEXT PAGE
Is the "Thermo Sensor Icon" displayed on the screen?
Check Point 3-1 : Check the remote controller
Hold down the THERMO SENSOR button until
thethermo sensor icon is turned off.
1. House insulation setting has not been changed.
2. Temperature sensing location has not been changed.
3. Installation location of the wired remote.
4. Function settings have not been changed.
Too warm
02-40