- 186 -
OUTDOOR UNIT
AOU24RLXFZH
Model: AOU24RLXFZH
Heating
1) Non-ducted
2) Ducted
NOTES:
Specifications are based on the following conditions.
• Power source of specifications: 230 V
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h, 14: 14,000 Btu/h, 18: 18,000Btu/h
• 2 indoor units should be connected.
• Heating: Indoor temperature of 70 °FDB (21.1 °CDB)/ 60 °FWB (15.6 °CWB), and outdoor
temperature of 47 °FDB (8.3 °CDB) / 43 °FWB (6.1 °CWB).
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
• The total ability of connected a indoor unit is up to 21,000 Btu from 14,000 Btu.
• Non-Ducted system combinations input are based on ASU wall mount models. The input of
combinations including AUU cassette models may be a little higher.
• Ducted system combinations capacities are based on ARU slim duct units excepting 7,000-Btu
models. 7,000 Btu models are based on ASU wall mount models.
Combination of indoor unit
Rated capacity for each indoor
unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1 Room 2 Room 3 Total Room 1 Room 2 Room 3 Room 1 Room 2 Room 3 Min. Rated Max. Min. Rated Max.
7 7 - 14 9.50 9.50 - 11.10 11.10 - 6.80 19.00 22.20 0.52 1.38 1.92
7 9 - 16 9.20 11.80 - 10.70 13.80 - 6.80 21.00 24.50 0.52 1.58 2.50
7 12 - 19 8.30 14.20 - 9.70 16.70 - 6.80 22.50 26.40 0.52 1.92 2.64
7 15 - 22 7.80 15.60 - 9.17 18.33 - 6.80 23.40 27.50 0.50 1.93 2.74
7 18 - 25 6.80 17.50 - 7.90 20.40 - 6.80 24.30 28.30 0.50 1.94 2.85
9 9 - 18 11.10 11.10 - 12.70 12.70 - 6.80 22.20 25.40 0.52 1.75 2.62
9 12 - 21 10.00 13.40 - 11.70 15.60 - 6.80 23.40 27.30 0.52 2.01 2.66
9 15 - 24 9.30 14.50 - 10.90 16.90 - 6.80 23.80 27.80 0.50 1.96 2.75
9 18 - 27 8.10 16.20 - 9.67 19.33 - 6.80 24.30 29.00 0.50 1.92 2.85
12 12 - 24 12.10 12.10 - 14.20 14.20 - 6.80 24.20 28.40 0.52 2.10 2.85
12 15 - 27 11.20 13.10 - 13.60 15.90 - 6.80 24.30 29.50 0.50 1.93 2.85
7 7 7 21 8.10 8.10 8.10 9.50 9.50 9.50 6.80 24.30 28.50 0.50 1.76 2.77
7 7 9 23 7.60 7.60 9.80 9.07 9.07 11.66 6.80 25.00 29.80 0.50 1.81 2.85
7 7 12 26 6.70 6.70 11.60 8.08 8.08 13.85 6.80 25.00 30.00 0.50 1.80 2.85
7 9 9 25 7.00 9.00 9.00 8.40 10.80 10.80 6.80 25.00 30.00 0.50 1.80 2.85
9 9 9 27 8.33 8.33 8.34 10.00 10.00 10.00 6.80 25.00 30.00 0.50 1.79 2.85
Combination of indoor unit
Rated capacity for each indoor
unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1 Room 2 Room 3 Total Room 1 Room 2 Room 3 Room 1 Room 2 Room 3 Min. Rated Max. Min. Rated Max.
7 7 - 14 9.50 9.50 - 11.10 11.10 - 6.80 19.00 22.20 0.52 1.42 1.94
7 9 - 16 9.20 11.80 - 10.70 13.80 - 6.80 21.00 24.50 0.52 1.62 2.52
7 12 - 19 8.30 14.20 - 9.70 16.70 - 6.80 22.50 26.40 0.52 1.97 2.69
7 18 - 25 6.80 17.50 - 7.90 20.40 - 6.80 24.30 28.30 0.50 1.99 2.93
9 9 - 18 11.10 11.10 - 12.70 12.70 - 6.80 22.20 25.40 0.52 1.80 2.63
9 12 - 21 10.00 13.40 - 11.70 15.60 - 6.80 23.40 27.30 0.52 2.06 2.71
9 18 - 27 8.10 16.20 - 9.67 19.33 - 6.80 24.30 29.00 0.50 1.97 2.93
12 12 - 24 12.10 12.10 - 14.20 14.20 - 6.80 24.20 28.40 0.52 2.15 2.93
7 7 7 21 8.10 8.10 8.10 9.50 9.50 9.50 6.80 24.30 28.50 0.50 1.83 2.85
7 7 9 23 7.60 7.60 9.80 9.07 9.07 11.66 6.80 25.00 29.80 0.50 1.89 2.93
7 7 12 26 6.70 6.70 11.60 8.08 8.08 13.85 6.80 25.00 30.00 0.50 1.88 2.93
7 9 9 25 7.00 9.00 9.00 8.40 10.80 10.80 6.80 25.00 30.00 0.50 1.88 2.93
9 9 9 27 8.00 8.00 8.00 10.00 10.00 10.00 6.80 25.00 30.00 0.50 1.87 2.93