Detailed technical specifications for indoor and outdoor units, including capacity, input power, and dimensions.
Physical dimensions and installation space requirements for indoor and outdoor units.
Safety precautions and guidelines for service personnel and handling of the equipment.
Detailed list and diagrams of all parts for the indoor units.
Detailed list and diagrams of all parts for the outdoor units.
List of included accessories for indoor and outdoor units.
List of optional parts, including remote controllers and sensors.
Diagrams illustrating the refrigerant circuit for different models.
Electrical wiring diagrams for outdoor units.
Diagrams of the main PCB and other electronic boards.
Explanation of how error codes are displayed on indoor and outdoor units.
Step-by-step troubleshooting procedures for specific error codes.
Troubleshooting steps for issues occurring without specific error codes.
Details on compressor frequency control during startup, basic range, and temperature limits.
Explanation of the compressor preheating function to prevent oil and refrigerant mixing.
Automatic switching of operation modes based on temperature and conditions.
Indoor fan speed settings based on operation mode and airflow.
Outdoor fan speed settings based on operation mode and temperature zones.
Settings for ON/OFF timer, weekly timer, and set back timer.
Function to prevent overcooling by maintaining a minimum heating temperature.
Operation mode that adjusts target temperature for energy saving.
Procedures for performing test runs using wired or wireless remote controls.
Forced operation modes for test runs or pump down without a remote.
Conditions and flowcharts for starting and completing defrost operations.
Automatic defrost operation when frost adheres to the heat exchanger in heating mode.
Prevents the compressor from restarting for 3 minutes after stopping.
Controls the 4-way valve switching based on mode changes and compressor stops.
Automatic resumption of operation after a power interruption.
Control of the electronic expansion valve based on various sensor readings.
Over-temperature, over-current, and other protection functions.
Procedure for safely recovering refrigerant before moving or discarding the unit.
Adjusting various functions of the indoor unit via PCB components or remote.
Setting functions on the outdoor unit control board using DIP switches.
Procedures for test runs, error code display, and pump down operations.
Configuring external inputs, outputs, and their combinations.