3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
ASUH09LMAS ASUH12LMAS
Heating
POWERFUL 1,250 1,270
HIGH 1,180 1,200
MED+ 1,040 1,100
MED 970 1,030
LOW 810 880
QUIET 630 630
Cool air prevention 550 550
S-LOW 400 470
Cooling
POWERFUL 1,180 1,180
HIGH 1,110 1,110
MED 920 920
LOW 760 760
QUIET 550 550
S-LOW 400 470
Fan
POWERFUL 1,180 1,180
HIGH 1,100 1,110
MED 920 920
LOW 760 760
QUIET 550 550
Soft quiet 470 470
Dry
X zone: 550
J zone: 550
X zone: 550
J zone: 550
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-7) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS