EasyManuals Logo

Fujitsu AOYA45LATL User Manual

Fujitsu AOYA45LATL
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
50 Installation and operating manual “1350-EN”
Heat pump, Split, single service
Configuration 3 :
2 heating circuits
Circuit 2
Circuit 1
CC2
M
VM1
CC1
SA2
SA1
K2c
SDp1
SE
R
SP
CAR
CAR
Circuit 2
Circuit 1
CC2
M
VM1
CC1
SA2
SA1
K2c
SDp1
SE
R
SP
1
2
3
4
5
11
12
13
14
5
6
AVS
20
Legend
CAR - Non-return valve
CC1 - Heating circulation pump, Circuit 1 (Remote heat
pump circulation pump)
CC2 - Heating circulation pump, Circuit 2
K2c - 2nd circuit kit
R - Radiators (or fan convectors)
SA1 - Room thermostat, Circuit 1 (option)
SA2 - Room thermostat, Circuit 2 (option)
SE - Outdoor sensor
SDp1 - Flow sensor, Circuit 1
SP - Heated floor thermal safety fuse
VM1 - Mixer valve, Circuit 1
Overview of all the electrical connections
Overall hydraulic layout
F
See detailed instructions
on Page 47

Table of Contents

Other manuals for Fujitsu AOYA45LATL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYA45LATL and is the answer not in the manual?

Fujitsu AOYA45LATL Specifications

General IconGeneral
BrandFujitsu
ModelAOYA45LATL
CategoryAir Conditioner
LanguageEnglish

Related product manuals