TERMINAL
INDOOR UNIT OUTDOOR UNIT
2013.01.21 4
CIRCUIT DIAGRAM
BLACK
WHITE
BLACK
WHITE
GREEN
BLACK
RED
RED
BLACK
WHITE
YELLOW
BROWN
RED
BROWN
BLUE
ORANGE
YELLOW
WHITE
BLACK
BLACK
BROWN
BROWN
BLACK
BLACK
BLUE
BLUE
BROWN
BROWN
RED
RED
VIOLET
WHITE
YELLOW
BLUE
BLACK
RED
BROWN
ORANGE
ORANGE
ORANGE
RED
WHITE
BLACK
BROWN
RED
ORANGE
YELLOW
WHITE
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
BLACK
BLACK
BLACK
GRAY
9
CN301
8
7
654
32
1
98
7
654
32
1
12
3
456
78
9
WHITE
12
3
456
78
9
12
34
5
1
2
34
5
5
4
32
1
5
4
32
1
2
1
2
1
4
32
1
4
32
1
5
4
32
1
5
4
32
1
6
6
2
1
2
1
2
1
2
1
1
2
7
6
5
4
3
2
1
7
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
2
1
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
2
1
2
1
CN303
W306
W307
TM302
TM301
W17
W16
TM102
TM101
TM303
W
TM304
V
TM305
U
W4
CN1
CN110
CN100
TM600
TM601
W29
W28
W25
W26
W3
W18
W17
W2
W1
W21
W9
W20
W19
L1L2
N
P
- I N
+ I N
CN11
W8
W7
W13
W12
CN400CN200CN40CN42
S
R
T
CN800
CN700
CN500
CN63
CN65
CN62
CN64
CN90
COMPRESSOR
CM
POSISTOR
(36 only)
CHOKE COIL
TERMINAL
FUSE
250V 25A
1 2 3 L
N
POWER SOURCE
FM
PMV
4WV
4-WAY VALVE
EXPANSION
VALVE
FAN MOTOR
THERMISTOR
( DISCHARGE TEMP. )
THERMISTOR
( PIPE TEMP. )
THERMISTOR
( OUTDOOR TEMP. )
THERMISTOR
( COMPRESSOR TEMP. )
HIGH PRESSURE SWITCH
ACTPM
CAPACITOR PCB
FILTER PCB
TRANSISTOR
PCB ( I P M )
MAIN PCB
1 2 3
MAIN PCB
INDICATOR PCB
( OPTION )
EX. IN EX. OUT
( OPTION )
1
2
3
1
2
1
2
E101
E102
CN102
CN103
CN106
1
2
DRAIN PUMP
MOTOR
M
TERMINAL
YELLOW
YELLOW
GREEN
GREEN
W105
W102
W101
F101
3.15A
250V
CN105
CN104 CN101
POWER
SUPPLY
PCB
BROWN
YELLOW
WHITE
BLACK
RED
1
2
3
4
5
6
1
2
3
4
5
6
F M
FAN MOTOR
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
1
2
3
4 5 6 7 8
1
2
3
1
2
3 4 5 6 7 8
1
2
3 4 5 6 7 8
1
2
3
4 5 6 7 8
1
2
3
1
2
3
1
2
3
1
2
1
2
1
2
1
2
1
2
CN4 CN1
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
1
2
3
1
2
1
2
3
4
5
6
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
1
2
3
1
2
1
2
RED
BROWN
ORANGE
BLUE
YELLOW
GREEN
BLACK
RED
WHITE
BLACK
BLACK
BLACK
RED
ORANGE
YELLOW
PINK
BLUE
CN3
CN13
CN14
CN6
CN10
CN9
CN11
CN12
RED
ORANGE
YELLOW
PINK
BLUE
TERMINAL
TO FRESH AIR SWITCH
( OPTION )
TO WIRED
REMOTE
CONTROL
1
2
3
THERMISTOR
( ROOM TEMP. )
THERMISTOR
( PIPE TEMP. )
BLACK
BLACK
RED
RED
FLOAT SWITCH
M
M
LOUVER
( RIGHT / LEFT )
LOUVER
( UP / DOWN )
RED
WHITE
BLACK