6. OUTDOOR FAN CONTROL
Cooling Dry Heating
AWYZ14/18LBC 820/670/500
400/340/300
300/250/220
( Table 8 : Outdoor fan speed )
*
The outdoor fan speed mentioned avobe depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequescy decreases, the outdoor fan speed also changes to the
lower speed.)
*
It runs at 200(E,F ZONE) rpm for 20 seconds after starting up the outdoor fan.
05-07
A-D
E
F
ZONE
500/450
400/340/300
300/250/220
820/730/670/550/450
Refer to Fig1.
(rpm)
* After the defrost control is operated on the heating mode, the fan speed keeps at 950rpm
without relating to the compressor frequency.
(1). Outdoor Fan Motor
AC Motor DC Motor
AWYZ14/18LBC
(2). Fan Speed
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.