| Cooling Capacity | 4.0 kW |
|---|---|
| Heating Capacity | 5.0 kW |
| Energy Efficiency Ratio (EER) | 3.21 |
| Coefficient of Performance (COP) | 3.61 |
| Refrigerant | R32 |
| Outdoor Unit Dimensions (W x H x D) | 790 x 540 x 290 mm |
| Indoor Unit Weight | 9.5 kg |
| Outdoor Unit Weight | 32 kg |
| Type | Split |
| Power Supply | 230V / 50Hz |
| Noise Level (Outdoor Unit) | 48 dB(A) |
Details compressor frequency control based on room and outdoor temps.
Explains compressor frequency control in heating mode based on room and outdoor temps.
Describes compressor frequency control in dry mode based on room temp and set temp.
Explains automatic switching between heating, cooling, dry, and monitoring modes.
Covers fan speed settings, airflow modes, and operation in cooling and dry modes.
Details outdoor fan motor types and speed control based on operating conditions.
Explains vertical and right-left louver adjustments and swing operations.
Covers compressor frequency range, start-up control, and limitations by outdoor temp.
Details wireless remote timer settings: ON/OFF, Program, Sleep, Weekly.
Explains EEV opening calculation and control based on operating conditions.
Provides methods for performing test operations using the indoor unit or wired remote.
Specifies compressor delay before restarting after a stop.
Describes four-way valve switching from cooling to heating mode.
Details automatic restart with previous settings after a power failure.
Explains operating the unit via manual auto button when remote control is unavailable.
Describes forced cooling operation, which runs regardless of room temperature.
Explains compressor heating before operation for warm air discharge.
Details the 10°C HEAT operation mode and its settings.
Describes ECONOMY mode for reduced output and energy saving.
Explains OUTDOOR UNIT LOW NOISE operation for reduced sound levels.
Details POWERFUL OPERATION mode for maximum power output for rapid cooling/heating.
Explains conditions and procedures for starting and completing defrost operation.
Describes automatic defrost operation when the unit stops in heating mode.
Covers discharge gas temp over-prevention and current release controls.
Lists error codes and display patterns for indoor units and wired remotes.
Guides troubleshooting for serial communication errors between indoor and outdoor units.
Guides troubleshooting for "Indoor Unit - No Power" issues without specific error codes.
Provides troubleshooting for "No Cooling / No Heating" issues without specific error codes.
Explains indoor unit function settings: filter sign, room temp correction, auto restart.
Step-by-step guide to changing function settings using the wireless remote control.
Lists resistance and voltage values for indoor/outdoor unit thermistors at various temperatures.