2. TROUBLESHOOTING
02-01
2-1 ERROR DISPLAY
2-1-1 INDOOR UNIT AND WIRED REMOTE CONTROLLER DISPLAY
Please refer the flashing pattern as follows.
Indoor Unit : ASYG07/ 09/ 12/ 14LECA
The OPERATION, TIMER and ECONOMY lamps operate as follows according to the error contents.
Manual auto switch error
Indoor room thermistor error
Indoor unit model information error
EEPROM access abnormal
Wired remote controller
communication error
Error Contents
Continuous
Continuous
4 times
Continuous2 times
3 times
3 times
5 times
Continuous2 times1 times
Continuous1 times1 times
Trouble
shooting
(Green)
(Orange)
(Green)
1 times
Serial communication error
Indoor unit fan motor error
Indoor heat Ex. thermistor error
Continuous4 times 2 times
Continuous1 times5 times
Outdoor unit main PCB error
2 times6 times
Continuous
Continuous
4 times
7 times
6 times
1 times
Continuous
7 times 3 times
Continuous
7 times 4 times
Continuous
PFC circuit error
Discharge thermistor error
Heat Ex. liquid outlet
thermistor error
Outdoor thermistor error
1
2
3
4
5
6
7
9
10
11
12
13
14
15
16
17
18
19
20
Continuous8 times 4 times
Current sensor error
Continuous
Continuous
Continuous
5 times
9 times
9 times
7 times
Compressor control error
Outdoor unit fan motor error
Continuous
4 times9 times
Continuous
9 times 9 times
4 Way valve error
1 times10 times
Discharge temp. error
Over current error
Continuous
5 times6 times
IPM error
Indoor Unit Display
Wired Remote
Controller
Display
11
12
32
35
41
42
51
62
64
65
71
73
74
84
94
95
97
99
A1
OPERATION TIMER
ECONOMY